Specifications

System Programming IMl66-107
Video Display Terminal Programming Procedure
-
continued
Remote Programming Configuration
-
continued
If you are employing remote programming,
the
data parameters of the PC must match the modem
connected to it. The modem connected to the
digital telephone system must match the data
parameters of it as well.
NOTE:
Remember,
&bit
data is required for XMODEM
protocol. If the digital telephone system is not
now programmed to provide
&bit
data, you will
have to reprogrammed it from station
70
before
data communications can take place. You
should set the baud rate to match the modem
or the PC at the same time.
3.
Set the data communication parameters as follows:
0
Press ALT P.
0
Type
11
the press
ENTER.
This action selects a
baud rate of 9600 baud.
NOTE:
Remember, the baud rate setting of the
PC
Or
data terminal, the data modems, and the digital
telephone system must be the same.
0
Type 17 then press
ENTER.
This action selects
6-bit data.
0
Type
18
the press
ENTER.
This action selects
one stop bit.
0
Type 24 then press
ENTER.
This action saves the
data parameters.
4.
Set the terminal parameters as follows:.
0
Press ALT S.
0
Type 2 then press ENTER.
0
Type
1
then press ENTER.
0
Use arrow keys to select VDT-100 or similar
emulation then press ENTER.
NOTE:
Settins the t&nnina/ emulation for a Wyse-50 or
VT-
100
emulation will provide a comp&ible set
of default values; however, any emulation
which provides full duplex operation is
satisfactory.
Press ESC to finish.
Press S then press ENTER. This action saves the
terminal parameters.
Press ESC then press ENTER to end the terminal
parameter set up.
5.
6.
7.
6.
9.
When computer screen displays a prompt for
password, type I
++
7 4 6
+K
then press ENTER.
This causes main COS programming menu to be
displayed.
From main menu, type
1
then press ENTER. This
causes system COS programming menu to be
displayed.
From system menu, make all selections necessaty
to perform class of service programming then
return to the main menu.
From the main menu, type 4 then press ENTER.
This causes load/save menu to be displayed.
From load/save menu, down-load COS data from
digital telephone system to computer or up-load
COS data from computer to digital telephone
system,
Down-Load COS Data From Digital
Telephone System To PC
Type
1
then press ENTER.
Press PAGE DOWN.
Type
1
to choose XMODEM protocol.
Type file name for down-loaded COS data to save
into.
Press ENTER. The COS data, as programmed in
the digital telephone system, is automatically
down-loaded to the computer file.
Up-Load COS Data From PC
To Digital Telephone System
Type 2 then press ENTER.
Press
PAGE UP.
Type
1
to choose XMODEM protocol.
Type file name of saved COS data.
Press ENTER. The COS data, as stored in the
computer file, is automatically up-loaded to the
digital telephone system.
10. Repeat step 6 except type 3 to down-load
currently stored auto dial and speed dial numbers
or type 4 to up-load them.
11. Return to main menu and log off.
4-80