VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of VALVE BODY.
Re-assemble CARTRIDGE. Install trim. Turn on water supply and check for leaks.
REPLACING CARTRIDGE (FIGURE 1)
To remove CARTRIDGE (1), install split WASHER (3) (only supplied with replacement cartridge). as shown.
Proceed to unthread BONNET NUT (2) counter clockwise.
Note: CARTRIDGE (1) should be pulling out while unthreading BONNET NUT (2).
Upon removal of the old Cartridge, install a new cartridge and secure it with BONNET NUT (Hand tighten).
BACK TO BACK INSTALLATION (FIGURE 2, 3 & 3A)
• Remove CARTRIDGE (1).
• Remove venturi tube by pushing it out. As shown in FIGURE 3.
Rotate CARTRIDGE (1) 180˚ so that the Up text is displayed on the bottom side. As shown in FIGURE 2.
• Reinstall the venturi tube by pushing it in. As shown in FIGURE 3A.
• Insert Cartridge back into the valve.
• Reassemble BONNET NUT (2) and hand tighten.
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
6
Remove HANDLE (see step 3 and reverse).
Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).
SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING
Figure 1.
1
3
2
Figure 2.
Standard
Back to Back
ROTATE 180°
Figure 3. Figure 3A.
PUSH UP
PUSH DOWN
CAUTION
Turn off hot and cold water
supplies before beginning.