Installation Guide
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
M985081 (1/21)
- 3 -
• By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1)
reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet valve, adjust the setting on the HOT LIMIT
SAFETY STOP (1).
• Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP (1). Pull forward and rotate
counterclockwise one number to limit hot water temperature.
Use NUMBERS (5) on CARTRIDGE (4) on HOT LIMIT STOP (1)
for indication.
ADJUST HOT LIMIT STOP
COLDER
(Larger Numbers)
1 2 3 4 5 6 7 8 9 10
HOTTER
(Smaller Numbers)
1 2 3 4 5 6 7 8 9 10
3
4
1
5
2
BACK TO BACK INSTALLATION
• Remove CARTRIDGE (B) as detailed in steps above.
• Remove PIN (A) from CARTRIDGE (B) by pulling.
• Separate MANIFOLD (C) from CARTRIDGE (B) by pulling.
• Rotate CARTRIDGE (B) 180 degrees and reinstall MANIFOLD (C)
with PIN (A).
• The “UP” TEXT (D) should now be facing downward during
installation of the CARTRIDGE (B).
SERVICE
CAUTION
Turn off hot and cold water
supplies before beginning.
B
A
B
C
180º
B
A
B
D
1 2
3 4
BACK TO BACK INSTALLATION
Standard
Back to Back
DIVERTER TYPE FUNCTION
2-way discreet
Left
Port
Top Port
3-way shared
Left
Port
Right
Port
SharedShared
Top Port
Shared
2-way shared
Left
Port
Shared
Top Port
3-way discreet
Left
Port
Right
Port
Shared (trickle ow)
Shared
(trickle ow)
Shared
(trickle ow)
Top Port