Installation Instructions

4
- 3 -
M965821 (8/17)
Loosen SET SCREW (1) with HEX WRENCH (2). Pull off HANDLE (3). Remove HANDLE SCREW (4) and
HANDLE ADAPTER (5). Pull off HANDLE BASE (5).
Check that arrow marking B points to the 3 o’clock position. If not, push the RED CLAMP on
the SECURING RING to the right, pull off KNOB MOUNT (6) and reinstall KNOB MOUNT (6) with arrow “B” 3
o’clock position. See Figure 1.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109˚F at the factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Red Plastic part). Re-install it at the desired notch as
indicated in the diagram to limit the maximum mixed water temperature to 104˚F or 112˚F.
For 100˚F adjustment, turn the water supply on. Turn KNOB MOUNT (6) until the spout temperature is 100˚F.
Check that arrow “A” on the KNOB MOUNT (6) still points 3 o’clock position after adjusting the thermostat to
100˚F. If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT (6) by pulling it towards you while
standing directly in front of the valve.
Reinstall the KNOB MOUNT (6) with arrow “A” 3 o’clock position.
Re-install RED LOCKING DEVICE (5).
See step 2 for HANDLE (3) installation.
TEMPERATURE ADJUSTMENT
6
1
6
4
ARROW
"A"
BLACK
CLAMP
ARROW
"B"
RED LOCKING
DEVICE
TEMPERATURE
LIMIT STOP
ARROWS AT 3 O'CLOCK
POSITION
Figure 1
KNOB MOUNT
112
109
104
2
3
5