Installation Guide
- 4 -
M965907 (5/18)
TEST PROCEDURES FOR FLUSH PLUG (SOLD SEPARATELY)
3
2
1
3
4
n Unthread BONNET NUT (3).
n Remove TEST CAP (1) and install FLUSH PLUG (2).
n Rotate FLUSH PLUG (2) so opening for inlet (HOT or COLD) directs water ow to selected outlet (SHOWER or TUB).
n Secure FLUSH PLUG (2) by tightening BONNET NUT (3).
n Check for leaks and ush lines.
n Repeat steps above to Test/Flush atlernate ow paths.
n Upon completion, unthread BONNET NUT (3). Remove FLUSH PLUG (2), replace with TEST CAP (1), and tighten
BONNET NUT (3).
CAUTION
Turn off hot and cold water
supplies before beginning.
SERVICING
4
n To replace SCREW DRIVER STOP (4), unthread it counterclockwise using the hex wrench.
n Replace the unit with a new SCREW DRIVER STOP (4).