Installation Instructions
M968257
FLUSHING THE VALVE
2
Water should be flushed through the piping to prevent
clogging of the
Thermal Element.
Remove PLASTER GUARD (1).
Turn ADAPTER (2) on volume control clockwise until
it reaches the stop.
CAUTION
IMPORTANT:
Close both CARTRIDGES (9, 9a) by rotating GEARS (7) counterclockwise.
Replace CLUTCH DRIVE SHAFT (5) and CLUTCH COVER (4) with SCREWS (3).
Turn VOLUME CONTROL HANDLE 180 to synchronize the
HOT and COLD CARTRIDGES.
Turn on water supply and check for leaks.
Replace BACK PLATE (8). Assemble both GEARS (7) with the flat side
facing BACK PLATE (8) and tighten SCREWS (6).
MAX
PLASTER
GUARD
SCREWS
1
2
3
4
5
7a
7
8
9
9a
6
6a
Turn off hot and cold water supplies
before beginning.
ROUGHING-IN THE VALVE
WARNING
1
Decide on desired configuration.
DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL
DAMAGE THE TEMPERATURE CONTROL ELEMENT.
Prepare water supplies per ROUGHING-IN DIMENSIONS.
Install VALVE at indicated height and depth.
Connect HOT water supply to inlet marked with the RED DOT and
COLD water supply to inlet market with the BLUE DOT.
Secure VALVE body to cross brace of wall structure.
Important! Install any required shut off or diverter valves into the piping system.
Assemble the CONNECTING PIPE to one of the MIXED OUTLETS of the VALVE.
Note
: The tub port is fitted with a plug at the factory.
Turn off hot and cold water supplies
before beginning.
CAUTION
HOT
INLET
COLD
INLET
MIXED
OUTLET
PLASTER
GUARD
SCREWS
PLASTER
GUARD
VALVE
BODY
CROSS
BRACE
MAX
Pull off ADAPTER (2).
Remove CLUTCH COVER SCREWS (3) and CLUTCH COVER (4).
Pull out CLUTCH DRIVE SHAFT (5).
Loosen the SCREWS (6) in the center of the GEARS (7). Remove
the GEARS (7) and BACK PLATE (8).
Remove the COLD CARTRIDGE (9) using a 22mm socket wrench.
Turn on MAIN COLD WATER SUPPLY to flush line.
Reassemble COLD CARTRIDGE (9) and repeat flushing steps for
HOT side (9a).
1
3
5
2
4
TEMPERATURE CALIBRATION
SET HOT LIMIT STOP
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3)
and reinstall KNOB MOUNT (3) with arrow "B" pointing vertically upwards.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout
temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points
upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5).
Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part).
Reinstall it at the desired notch as indicated in the diagram to limit the maximum
mixed water temperature to 104 F or 112 F.
Reinstall RED LOCKING DEVICE (5).
ARROW
"A"
ARROW
"B"
104
109
112
3