Operating instructions

Pub. No. 18-HE56D1-9 9
Installer's Guide
NOTE: The gauge must align with the cabinet per Figure 26.
The gauge must be in the same plane as the Field Charger
contact to be able to read it properly.
Figure 26
Figure 27
Figure 25
Use Gauge to determine which insulation spacer to
install by placing gauge in cabinet as shown in Figures
25 through 27. Read the gauge by viewing where the
flat of the Field Charger contact falls on a step. See
Figure 27.
12.
Airflow
NOTE: These two edges must
be flush with the cabinet sides.
Contact
NOTE: In order
to get the
proper reading,
The gauge must
line up with the
contact.
If Field Charger
contact falls in
this "step",
then use the
spacer that is
marked with
two dots.
If Field Charger contact
falls in this "step", then
use the spacer that is
marked with one dot.
If Field Charger contact falls in
this "step", then use the spacer
that is marked with three dots.