Operating instructions
18 Pub. No. 18-HE56D1-9
Installer's Guide
▲
CAUTION
!
Do NOT operate the air cleaner during construction or
remodelling of a home. The air cleaner is designed for use in
normal living conditions to capture small particles. The
volume of dust and condensate in the presence of chlorides
and fluorides from paint, varnish, stains, adhesives, clean-
ing compounds, and cement creates a corrosive condition
which may cause rapid deterioration of the cabinet and
internal components of the air cleaner and the air handler/
furnace.
DISPLAY FEATURES (Figure 40)
The air cleaner display can be used for several functions:
• Provide the homeowner the operating status of the air
cleaner, including an indication the PRE-FILTER or
COLLECTION CELLS need cleaning.
• The installer accesses the Set-Up Mode to change the
time to clean settings for the PRE-FILTER and
COLLECTION CELLS as well as change the Power
Level setting.
• The unit will display fault codes for the homeowner
indicating there is a problem with the air cleaner and
various fault codes for the service technician to assist in
troubleshooting the problem.
Turn the air cleaner on by pushing the POWER button. The
backlit POWER and filter RESET buttons will illuminate
along with the first Green LED (G1) indicating 24 Volt power
is present to the air cleaner.
When the indoor fan is operating the first LED (G1) will
slowly flash. This indicates the FIELD CHARGER and
COLLECTION CELLS have power and the unit is operating
normally. There is a ten minute time delay between the
indoor fan starting and LED (G1) flashing.
In normal operation, the air cleaner makes a slight sound as
the air passes through it and is cleaned. In some
applications, you may notice this sound coming from the
return air vent(s). If desired, this sound level can be reduced
with minimal impact on air cleaning efficiency by reducing
the power setting of the FIELD CHARGER in the Set-Up
Mode.
NOTE: There is a 10 minute delay after the indoor fan
operates, before the air cleaner starts to operate, each
time the power to the air cleaner is turned off/on. This can
be bypassed by going into and then out of the Set-Up
mode.
G. SET-UP MODE
A combination of RED, YELLOW, and GREEN LED's are
used to indicate the following settings. See Figure 41.
• The three GREEN LED's are used to indicate PRE-FILTER
cleaning interval. This is measured in actual run time of the
indoor fan. The default setting is 2 months. See Figure 42.
• The four YELLOW LED's indicate the COLLECTION CELL
cleaning interval. This is measured in actual run time of the
indoor fan. The default setting is 6 months. See Figure 43.
• The three RED LED's indicate the power level setting. The
default is maximum. See Figure 44.
INSTALLER SET-UP MODE
To enter the Installer Set-Up Mode press and hold both the
POWER and RESET buttons for a minimum of 5 seconds.
The current settings are then displayed. See Figure 40. If
this is the desired setting or at any time you want to exit the
Set-Up mode, press and hold BOTH the POWER and
RESET buttons for a minimum of 5 seconds to exit.
G1
G2
G3
Y1
Y3
Y4
R1
R2
R3
Y2
CLEAN
DIRTY
Power Level
Collection Cell
Pre-Filter
Figure 41 Factory Settings
PRE-FILTER SETTING
(Figure 42)
To change any of the settings, press the POWER button
once.
One or more of the GREEN LED’s will come on indicating
the PRE-FILTER cleaning time setting. Repeatedly press the
RESET button to cycle through the time options for the PRE-
FILTER cleaning cycle until the desired setting is displayed.
Press the POWER button once to accept that setting and
move to the COLLECTION CELL cleaning settings.
1 Month 2 Months* 3 Months
G1
G2
G3
Y1
Y3
Y4
R1
R2
R3
Y2
CLEAN
DIRTY
G1
G2
G3
Y1
Y3
Y4
R1
R2
R3
Y2
CLEAN
DIRTY
G1
G2
G3
Y1
Y3
Y4
R1
R2
R3
Y2
CLEAN
DIRTY
Figure 42 Green LED Pre-Filter Settings
* Factory Setting
Figure 40 LED Display
F. AIR CLEANER OPERATION AND SET UP
PRE-FILTER
RESET
CLEAN
LED's
POWER
PRE-FILTER
RESET