User`s manual
SummaCut cutter User’s Manual
Specifications 6-7
6.3.7 ENVIRONMENTAL
(Cutter without media)
Operating Temperature
15 to 35° C
59 to 95° F
Storage temperature
-30 to 70° C
-22 to 158° F
Relative humidity
35 - 75 %, non condensing
35 - 75 %, non condensing
TABLE 9:
SUMMACUT ENVIRONMENTAL SPECIFICATIONS
IMPORTANT HINT
The use of dimensionally stable media is an essential pre-requisite to obtaining
high cut quality. Additionally, media expansion or contraction may occur as a
result of temperature variations.
To improve the dimensional stability of media, let it stabilize to the current
environmental conditions before usage for a minimum period of 24 hours
.
6.3.8 Electrical
The power entry module detects the line voltage and switches automatically between 110V
and 230V.
Main Supply: 48-62 Hz, single phase.
Nominal line
Min./Max. line
Fuse
110 V AC 88 - 132 V AC
T2.0A, 250V Schurter SPT or
equivalent.
230 V AC 176 - 264 V AC
T2.0A, 250V SCHURTER
SPT OR EQUIVALENT.
TABLE 10:
SUMMACUT ELECTRICAL SPECIFICATIONS
Power requirements: 100-120 / 220-240 VAC, 50/60 Hz, 85 VA maximum
6.3.9 Certifications
CE-Certification for electrical light industrial environment.
FCC Class A
Conforms to ANSI/UL Standard 60950-1
and certified to CAN/CSA Standard C22.2 No 60950-1
..