Service manual

WARNING
CLOSED WATER SYSTEMS
If the water supply system contains a check valve, back flow
preventer or water pressure reducing valve you will have closed
water system and the pressure will build up during the water
heating cycle. The temperature and pressure relief valve on the
water heater will leak during the water heating cycle resulting
in loss of energy. To prevent the build up of lime in the T&P
valve and damage to the water heater by pressure surges you
must install an expansion tank on the cold water supply line.
The tank should have a minimum capacity of 3 U.S. gallons.
It requires both T&P valves and expansion tanks for closed
system.
WARNING: FAILURE TO PROVIDE AN
EXPANSION TANK ON THE COLD WATER LINE
ON A CLOSED S YS TEM MAY VOID THE
WARRANTY ON THE WATER HEATER.
CONSUMER RESPONSIBILITIES
THIS MANUAL HAS BEEN PREPARED TO ACQUAINT
YOU WITH THE INSTALLATION, OPERATION AND
MAINTENANCE OF YOUR GAS WATER HEATER AND
TO PROVIDE IMPORTANT SAFETY INFORMATION.
WE URGE YOU TO READ ALL INSTRUCTIONS
THOROUGHLY
before attempting installation or operation of
your water heater. Keep these instructions for future reference.
The manufacturer of this water heater will not be liable for any
damages caused by failure to comply with the installation and
operating instructions outlined on the following pages. These
instructions are a guide for the correct installation of your
water heater. If you lack the necessary skills required or have
difficulty following the directions, you should not proceed but
get help from a qualified person for that part of the installation
you do not understand. Your gas-fired water heater is design-
certified by CSA International. The installation should
conform with the local code or the authority having
jurisdiction, or in the absence of such, the National Gas Code.
ANSI Z223.1 NFPA 54. A copy of the Code can be purchased
from American Gas Association Order Processing, 400 N.
Capital St. N.W. Washington D.C. 20001 e-mail ordering:
www.aga.org Fax ordering: 866-816-9444. A rating plate
identifying your water heater will be found next to the gas
control valve (thermostat).
1
FOR YOUR SAFETY
Do not use or store gasoline or any other flammable vapors, liquids, or
materials in vicinity of this or any other appliance.
FOR YOUR SAFETY - WHAT TO DO IF YOU SMELL GAS
• Do not try to light any
appliance.
• Do not touch any electrical
switch; do not use any phone
in your building.
• Immediately call your gas
supplier from a neighborʼs
phone. Follow the gas
supplierʼs instructions.
• If you cannot reach your gas
supplier, call the fire
department.
WARNING
Improper installation, ad-
justment, alteration, ser-
vice or maintenance can
cause injury or property
damage. Refer to this
manual. For assistance
or additional information
consult a qualified in-
staller, service agency or
the gas supplier.
Please complete the following information at the time of installation. This should be retained and presented along
with the warranty in the event a claim is necessary.
MODEL NUMBER: TYPE:
SERIAL NUMBER:
INSTALLATION ADDRESS:
THIS WATER HEATER HAS BEEN INSTALLED IN ACCORDANCE WITH THESE INSTALLATION
INSTRUCTIONS AND LOCAL CODE REQUIREMENTS ON
INSTALLER:
THIS WATER HEATER MUST BE PROPERLY AND REGULARLY MAINTAINED.
FAILURE TO DO SO WILL VOID THE WARRANTY.
Date