Product specifications
26
View the Current Schedule
1. Press the MENU button.
2. Scroll to Schedules and press the Select button.
3. Scroll to Heat and Cool and press the Select button.
4. The schedule for the current day will be displayed. To view other days, press the Next button.
Set a Heat and Cool Schedule
1. Press the MENU button.
2. Scroll to Schedules and press the Select button.
3. Scroll to Heat and Cool and press the Select button.
4. The schedule for the current day will be displayed. To view other days, press the Next button
5. To change a setting (hour, minute, day part, heat setpoint or cool setpoint), scroll to that setting using the left () or right () arrow buttons.
Then press the plus (+) or minus (-) buttons as necessary.
Î Continue pressing the left () or right () arrow buttons to move to the next line.
Copy a Day Schedule
1. Press the MENU button.
2. Scroll to Schedules and press the Select button.
3. Scroll to Heat and Cool and press the Select button.
4. The day of the week is displayed at the top of the screen. Press the Next button until the day you want to copy is displayed.
5. Highlight the small c in the lower right corner by pressing the left arrow () button once. The Next button will change to Copy.
6. Press the Copy button.
7. For each day to which you want to copy the day schedule, change the N (no) to Y (yes). Use the left () or right () arrow buttons to scroll
to the day and the use the Yes or No buttons on the side of the screen.
8. Press the Copy button.
Smart Continuous Fan (SCF) Operation
Smart Continuous Fan will provide for continuous fan operation to control humidity. To use SCF, you must enable SCF operation
in the Installers Settings menu under the Dehumidification Options menu. Set Smart Cont Fan to Y to enable it.
To turn on SCF, set the Fan mode to SCF.
When SCF fan mode is selected, the HVAC system fan will run continuously unless the humidity rises above the RH setpoint.
The RH setpoint is set in the User Settings menu. Default RH is set to 50%. SCF fan operation is turned off when RH is above
the setpoint. SCF operation is resumed at the end of the next cooling call.
Fan Mode
When RH% is above RH setpoint (Default is 50%)
SCF will turn continuous fan operation OFF.
Fan mode options will include SCF
when SCF is enabled in the Installers
Settings menu.
Status Line 2
Shows SCF Fan operation
when Fan Mode is set to SCF.
- Shows Fan Off when SCF
fan is not running.
- Shows Fan On when SCF
fan is running.
Note: Status display can be
overidden by other priority
system status messages.
MENU MODE FAN RUN
SCF
75
74 H
78 C
11:15 AM
RH%55
Fan Off