Installation Guide
7301793-100 Rev. F
5
WIRE HANGER
EYEBOLT
REMOVE THUMB NUT
FROM EYE BOLT
4. WIRE HANGER is positioned behind ELECTRONIC BOX
and in front of DRAIN.
5. Remove THUMB NUT from EYEBOLT.
13
15
CHECK ALL ELECTRICAL AND
PLUMBING CONNECTIONS
14
TEST INSTALLED FAUCET
INSTALL WIRE HANGER
1. Turn on water supplies and check for leaks.
Tighten any connections if necessary.
2. Check FAUCET operation, if adjustment is
required refer to the installation instructions
shown at right supplied with the IC FAUCET.
No. M965119.
1. Install EYEBOLT onto WIRE HANGER if not installed.
2. Place WIRE end in left SIDE HOLE.
3. Place WIRE end in right SIDE HOLE near DRAIN.
NOTE: If not enough tension, remove WIRE and spread
ends approx. 1" additional and re-attach.
6. EYEBOLT for SINK APRON.
No. M965119
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC
®
Proximity IC Faucet
Certified to comply with ASME A112.18.1M
© AS America, Inc 2013
To learn more about American Standard Faucets visit our website at: www.americanstandard.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-306-1093)
M965119
Product No.'s & Options
Specifications
How to Install
Electrical Hook-up
Maintenance
FAQ,s
Replacement Parts
1
2
2-3
4-6
7-8
9
10
6055.193
6056.193
MODEL NUMBERS
6055 / 6056 IC Faucet shown Installed on
American Standard 9118.111 ICS Sink
WIRE
WIRE
WIRE HANGER
EYEBOLT
TO ENSURE A LAMINAR WATER
FLOW the air must be slowly purged
from the spout. To do so, cover the
SENSOR (1) while slowly opening
the water supply valves. When the
water flows as a solid, smooth,
steady stream, uncover the
SENSOR (1) and fully open the
water supply valve.
DETECTION
ZONE
1