Installation Instructions
-7 - EN-
A ground fault circuit breaker must be installed in the circuit that supplies power to this product.
Ground Fault Circuit Breaker
Power Supply
Grounding
Installation Location
Water Supply
Unit : inch (mm)Remote control
1.18" (30 mm) or more
1.18" (30 mm) or more
8.15"
(207 mm)
8.62"
(219 mm)
47.24" (1200 mm) or more
15.75" (400 mm) or more
16.77"
(426 mm )
Elongated type: 21.5 (547 mm)
Round type: 20.8 (527 mm)
Checking the Bathroom
The dimensions required for mounting this product
on a toilet bowl are shown in the figure below.
Check to make sure there is sufficient space inside
the bathroom and that there are no obstructions.
DANGER:Improper use of the grounding plug may cause an electric shock.
Use only the tap water line to supply water to this product. The use of any other type of
water i.e. ground water may cause improper operation of this product.
The tap water pressure must be 8.5 to 106.7 psi (0.06 to 0.74 MPa, 0.6 to 7.5 kgf/cm
2
).
This product is for use on a nominal AC120 V circuit. Use a AC120 V, 60 Hz power supply. The
maximum power consumption is 1300W. Electrical wiring must be installed that meets these
specifications. The plug outlet shall be placed in an accessible location after installation.
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. The power cord has a grounding wire
and a three-prong grounding plug (shown below). Do not use an adapter with the product's power plug,
or use any other unauthorized method to connect the plug to an improperly configured outlet.
The outlet to which the product is connected must be AC120 V, 60 Hz, with a minimum electrical rating of
3 A. The outlet must be properly installed and grounded, and it must be a three-slot outlet (shown below).
In order to prevent damaging the electronic components, install this product at a location
that minimizes the possibility of it getting wet. In extremely humid conditions, provide
adequate ventilation by operating an exhaust fan or opening a window or door.
541 mm
(21-5/16")
414 mm
(16-5/16")
195 mm
(7-11/16")
219 mm
(8-5/8")
30 mm
(1-3/16")
or more
30 mm
(1-3/16")
or more