PCW-1361(19010) Installation Manual Advanced Clean 3.0 SpaLet ® Bidet Seat Model: 8018A60GRC Thank you for purchasing this product. CAUTION ● Carefully read this installation manual to install this product correctly. ● Be sure to test operation after installation has been completed. Installation Procedure 1 Check the "Installation Requirements"......................................... P.6 ↓ 2 Install the junction fitting.............................................................. P.
1. Important Safeguards When using electrical products, especially when children are present, the basic safety precautions should always be observed. READ ALL THE INSTRUCTIONS BEFORE USING THIS PRODUCT The following safety terms are used in this manual to warn against different hazardous situations: DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Low Temperature Burns A low temperature burn may occur when the skin has been in contact for some time with an object at relatively low temperature (about 104 °F [40 °C]). Susceptibility to burns also depends on an individual's skin sensitivity and other factors. 3. This product should be used only as described in this manual. Do not use attachments that are not recommended by the manufacturer. 4.
3. For care of the plastic parts, our company recommends the use of a mild, liquid, all-purpose cleaner. Avoid using abrasive products (such as powdered cleansers) and chlorine-based products (such as bleach), as these products can damage the anti-bacterial properties of the plastic components. ® 4. If the SpaLet seat or the body cover is damaged, pull the power plug out of the outlet and contact our company to request repairs. 5. Do not stand on the seat lid, as it may break. 6.
2. Product Description This product incorporates a set of features to improve personal toilet hygiene and comfort. These features include back cleansing, front cleansing, a warm air dryer and a seat heater as well as the required controls for these features. This product includes a SpaLet seat® unit (with heated SpaLet seat, seat lid, and power cord), hardware for installing the SpaLet seat unit on a toilet bowl and connecting it to the water supply and this installation and user manual.
3. Installing This Product Installation Requirements Before installing this product, ensure that each of the following installation requirements are met. Contents Remove the parts from the box and make sure all the parts in the parts list (below) are present. Inspect the parts carefully to make sure they are in good condition. If any part is damaged or missing, do not install this product. Contact the nearest customer service representative for the part(s) you need.
Ground Fault Circuit Breaker A ground fault circuit breaker must be installed in the circuit that supplies power to this product. Power Supply This product is for use on a nominal AC120 V circuit. Use a AC120 V, 60 Hz power supply. The maximum power consumption is 1300W. Electrical wiring must be installed that meets these specifications. The plug outlet shall be placed in an accessible location after installation. Grounding This product must be grounded.
Checking the toilet bowl 1. Measure the size of the toilet bowl. Depending on the size of the toilet bowl, it may not be possible to mount this product on it. Make sure the toilet bowl's dimensions are as shown in the figure on the right. 5.51" to 6.18" (140 to 157 mm) 15.35" (390 mm) or less 1.97" (50mm) or more 18.50" (470mm) or more 2. Conditions for using SpaLet® seat unit water supply hose (included) The length of the SpaLet seat unit water supply hose included with this product is 37.
Illustrated Parts Breakdown Overview Remote control unit (See page 11) Caution label Remote control unit (SeeTank page 10) Toilet seat lid Toilet tank Seat lid Junction fitting Marking label Caution label Seat sensor Junction Filter fitting (See below.) Product model nameplate SpaLet seat unit indicator section (See the enlarged view below.
Remote Control Bidet Cleansing Stop Spray Strength Transmitter Nozzle Position Dryer Water Temp. Deodorizer Seat Temp. Mild Massage Nozzle Cleaning Mounting Plate Mounting plate ® SpaLet seat unit Toilet bowl Lock lever * The mounting plate is used to remove the SpaLet seat unit from the toilet bowl for cleaning and maintenance.
Installation 1. Required tools Have the following tools for installing this product: adjustable end wrench, Phillips head screwdriver, flat-blade screwdriver. 2. Install the junction fitting (1) Close the toilet water shut-off valve fully. Bowl Cock Side Box Nut Tank Water Supply Hose (2) Flush the toilet and empty all the water from the toilet tank. (3) Place a wash bowl or other container underneath the tank water supply hose. Then loosen the box nut on the toilet tank inlet side and remove it.
3. Installation of SpaLet® seat unit water supply hose to the SpaLet seat 1) R emove the protective cover from the end of the SpaLet seat unit water supply hose, and pull out the cap from the water supply connection socket. Installation diagram Installation diagram 2) C onnect the SpaLet seat Water socket unitsupply waterconnection supply hose for the SpaLet seat to the water Protective cover supply connection socket.
4. Installation of the SpaLet® seat (1) Remove the existing seat. Installation diagram Seat mounting bolts 1) R emove the nuts from the seat mounting bolts, the slip washers, and rounded packing. Washer Mounting brackets CAUTION • When installing the SpaLet seat, make sure to use the parts provided in the installation kit. Mounting plate 2) R aise the seat and remove it by lifting the seat mounting bolts.
5. I nstall the SpaLet® seat unit water supply hose (junction fitting side) Junction Fitting Clip O-ring SpaLet seat unit Water Supply Hose Protective Cover (1) Remove the protective cover from the end of the SpaLet seat unit water supply hose, and insert it in the junction fitting. Junction Fitting O-ring CAUTION • Be careful not to damage the O-ring. * Water may leak if the O-ring is broken or damaged.
6. Positioning and Mounting the Remote Control ●● Remote control installation position Install the remote control to a position where the user can reach and operate it. Install the remote control in the area shown as “Suggested installation area” in the figure below, and ensure to install the remote control on a position where it can be operated easily ® while the user is seated on the SpaLet seat.
[Note 7-1] [Note 7-2] ●● Ensure to install the batteries in the correct direction (note the negative and positive). ●● Do not mix old and new batteries. ●● Use the supplied batteries. ●● Ensure that there is enough space above the remote control installation position to allow easy removal and mount of the remote control (see the figure below).
Test Operation Follow the procedure below after the installation work has been completed. 1. Insert the power plug into the outlet. ® Confirm that the power LED on the SpaLet seat unit is lit. Power plug Power plug Power indicator Power save indicator 2.Check the front and back cleansing spray. (1) Check the cleansing operation. Seat sensor switch 1) With your forearm resting on the SpaLet seat, press the Cleansing button. The spray automatically stops two minutes after the switch is turned on.
3. If the flushing begins to weaken, or if the nozzle spray seems to be getting weaker, clean the filters. (1) Turn the water shut-off valve clockwise to close it. As the water shut-off valve is pre-adjusted, keep track of the turns so that you can return to the original position. Water Water Valve Valve Turn Turn clockwise clockwise (2) Remove the filter located on the left side of the SpaLet® seat unit. Place a wash bowl or similar item underneath the Filter. Filter Filter (3) Rinse the filter.