Installation Guide
1.Turn the nozzle
anticlockwise
2.Pull out the
rubber plug
3.Remove the filter screen
from the rubber plug and
clean it. Re-install
after cleaning.
nozzle
rubber plug
filter screen
7
SERVICE AND MAINTENANCE
Sensor Adjustment:
• Move a magnet close to the sensor at the top of the
faucet. An LED light will flash continuously during the
adjustment. When the light stops flashing, the sensor
is now adjusted to its surroundings and should
operate normally when a hand/object is moved within
the sensor range.
Nozzle Cleaning:
• After a week of not being used there is a risk of soap build up in the nozzle. Follow these
steps to clean the nozzle after being idle:
Pump Maintenance:
• The soap pump may not be able to pump any liquid due to the machine being idle or the soap being
completely depleted before replacing the bottle.
1. Turn the nozzle
anticlockwise
2. Pull out the
rubber plug
3. Remove the filter screen
from the rubber plug and
clean it. Re-install after
cleaning.
1. Remove the soap connector as shown on the left
and ensure that the check valve is not clogged
due to soap.
2. Place the controller leveled, connect the power supply and press the start button on the
controller. After starting the motor to fill the gear pump with liquid, the controller can be
installed back into the soap bottle for normal use.