Installation Guide
- 3 -
8
9
• With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Remove AERATOR (3).
• Operate HANDLE (1) to ush water lines thoroughly.
• Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
• Fill lavatory with water. Check that DRAIN STOPPER (4)
makes a good seal and retains water in SINK.
• Release DRAIN STOPPER (4) down and check all drain
connections and “P” trap for leaks. Tighten if necessary.
• To remove or replace cartridge:
— Turn valve to OFF position.
— Pull out INDEX (1).
— Loosen SET SCREW (2). Pull off HANDLE (3).
— Pull off CAP (4).
— Pull out CARTRIDGE (5).
— Inspect CARTRIDGE (5) for debris and clean if necessary.
— Clean MANIFOLD (6) and rinse clean.
— Reinstall CARTRIDGE (5) onto MANIFOLD (6).
— Reinstall CAP (4) and HANDLE ASSEMBLY (3).
• If spout drips, operate handle several times from OFF to ON
and HOT to COLD position. Do not force
CARE INSTRUCTIONS:
TEST INSTALLED FITTING
7
M965899 (4/18)
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
• Operate DRAIN STOPPER (1) to verify that it opens
and closes.
SERVICE
CAUTION
Turn off hot and cold water
supplies before begining.
2
4
2
“P” TRAP
WASTE
OUTLET
1
OFF
ON
COLD
HOT
3
4
5
1
6
3
2
2.5mm
HEX KEY