Installation Guide

- 3 -
8
9
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Remove AERATOR (3).
• Operate HANDLE (1) to ush water lines thoroughly.
• Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Fill lavatory with water. Check that DRAIN STOPPER (4)
makes a good seal and retains water in SINK.
Release DRAIN STOPPER (4) down and check all drain
connections and “P” trap for leaks. Tighten if necessary.
To remove or replace cartridge:
— Turn valve to OFF position.
— Pull out INDEX (1).
— Loosen SET SCREW (2). Pull off HANDLE (3).
— Pull off CAP (4).
— Pull out CARTRIDGE (5).
Inspect CARTRIDGE (5) for debris and clean if necessary.
— Clean MANIFOLD (6) and rinse clean.
— Reinstall CARTRIDGE (5) onto MANIFOLD (6).
Reinstall CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON
and HOT to COLD position. Do not force
CARE INSTRUCTIONS:
TEST INSTALLED FITTING
7
M965899 (4/18)
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Operate DRAIN STOPPER (1) to verify that it opens
and closes.
SERVICE
CAUTION
Turn off hot and cold water
supplies before begining.
2
4
2
“P” TRAP
WASTE
OUTLET
1
OFF
ON
COLD
HOT
3
4
5
1
6
3
2
2.5mm
HEX KEY