Installation Guide
M968642
Turn off hot and cold water
supplies before beginning.
CAUTION
OFF
ON
COLD
HOT
4
5
TEST INSTALLED FAUCET
AND CHECK FOR LEAKS
SERVICE
1
2
3
COLD
HOT
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
6
1
2
4
5
6
2.5mm HEX KEY
REMOVE INSTALL
7
8
To remove or replace cartidge
Turn valve to OFF position.
Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean
if necessary.
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force - handles turn only 90˚.
3
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS: