TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
4
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
10
“P” TRAP
WASTE
OUTLET
1
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
OFF
ON
COLD
HOT
3
11
SERVICE
To remove or replace cartridge:
Turn valve to OFF position.
Pull out INDEX (1).
Loosen SET SCREW (2). Pull off HANDLE (3).
Pull off CAP (4).
Remove CARTRIDGE SCREWS (5).
Pull out CARTRIDGE (6).
Inspect CARTRIDGE (6) and O-RING (7) for debris and clean
if necessary.
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RING (7) onto MANIFOLD (8).
Reinstall CARTRIDGE SCREWS (5), CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force.
Turn off hot and cold water
supplies before beginning.
CAUTION
5
6
7
4
3
2
8
1
2.5mm HEX KEY