Installation & Assembly

M965780 (6/17)
12
13
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to ush water lines thoroughly.
Replace AERATOR (3).
SERVICE
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
TEST INSTALLED FITTING
10
4
HOT
1
1
COLD
2
2
“P” TRAP
5
WASTE
OUTLET
3
11
Operate POP-UP KNOB (5) and ll lavatory with water.
Check that DRAIN STOPPER (4) makes a good seal
and retains water in Sink. If DRAIN STOPPER (4)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (5) down and check all drain
connections and “P” trap for leaks. Tighten
if necessary.
CHECK DRAIN CONNECTIONS
90˚
90˚
2
6
3
1
4
5
8
7
5
Change Direction of the Handle
Turn valves to OFF position.
Turn off water supplies.
Pull HANDLE (1) “UP” rmly to release from ESCUTCHEON (6).
Remove SCREW (3) and pull off PLASTIC INSERT (2).
Remove CARTRIDGE NUT (8).
Remove RETAINING O-RING (4).
Lift and turn STOP WASHER (5) 90˚. Replace RETAINING
O-RING (4).
R e -install HANDLE ASSEMBLY.
To Change Cartridge:
Remove HANDLE (1), ADAPTER (2), SCREW (3) and CARTRIDGE
NUT (8) via steps above.
Remove cartridge by pulling upward on stem.
Aerator Clean Out
AERATOR may accumulate dirt causing distorted and reduced
water ow. Remove AERATOR by using the edge of a coin
and rinse to clear any debris.
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
- 4 -