Installation Guide
- 2 -
3
M965768 Rev. 1.0 (6/17)
• Feed SPRAY HOSE (1) through SPRAY HOLDER (2)
and attach COUPLING NUT (3) of HOSE (1) to
HOSE ADAPTOR (4).
FITTING WITH SPRAY
4
CONNECT SPRAY HOSE & INSTALL WEIGHTS
5
SERVICE
If faucet drips proceed as follows:
• Turn VALVE in OFF position.
• If faucet drips, operate handle several times from
“off” to “on”. Do not apply excessive force.
• Clogged CARTRIDGE inlets may cause reduced
ow in “full on” hot or cold. To clean inlets,
rst turn off water supply, then:
• Remove HANDLE (1), CAP (2), MOUNTING
SCREWS (5), ADAPTER (6), and CARTRIDGE (3).
Clean inlets and MANIFOLD (4). Reassemble
CARTRIDGE (3), alternately tightening screws.
Replace CAP and HANDLE. Check ow.
• Remove AERATOR. With handles in OFF
position, turn on water supplies and check
all connections for leaks.
• Operate both HANDLES to ush water lines
thoroughly. Rotate SPOUT in both directions.
Replace AERATOR.
• Direct SPRAY HEAD into sink and activate
SPRAY. Check HOSE connections for leaks.
2
1
4
3
AERATOR
1
2
3
4
6
5