Specifications

8
M965654 Rev. 1.2 (2/15)
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER
SCREW (4) at the back of the FAUCET. Pull FAUCET
COVER (1) up and off. See Fig. 2 in this section.
2. Disconnect SENSOR CABLE (1) from SOLENOID
CABLE (2). Fig. 8.
3. Unthread SOLENOID VALVE (2) from VALVE BODY
(3). Fig. 9.
4. Remove FILTER SCREEN (4) from base of SOLENOID
VALVE (2). Clean and replace. Fig. 9.
5. Thread SOLENOID VALVE (2) into VALVE BODY (3)
and hand tighten. Reconnect SENSOR and SOLENOID
CABLES (1). Fig. 8.
6. Replace FAUCET COVER (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this section.
CLEAN FILTER SCREEN ON
SOLENOID VALVE; Fig. 8 & 9
D
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER
SCREW (4) at the back of the FAUCET. Pull FAUCET
COVER (1) up and off. See Fig. 2 in this section.
2. Pull out LIMITER STOP (1) from the VALVE STEM
(2). Unthread COLLAR NUT (3) from VALVE BODY (4).
Fig. 10.
3. Pull DIVERTER CARTRIDGE (5) out and replace
with new DIVERTER CARTRIDGE (5).
NOTE: Make sure the two ALIGMENT PINS (6) in the
base of the DIVERTER CARTRIDGE (5) are facing
upward. Fig. 11.
4. Replace FAUCET COVER (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this section.
REPLACE DIVERTER CARTRIDGE;
Fig. 10 & 11
E
Fig. 9
4
2
3
4
2
1
Fig. 10
Fig. 12
9
8
Fig. 8
6
5
Fig. 11