Specifications

4
M965654 Rev. 1.2 (2/15)
Unit #1
(Already Installed)
Fig. 3
Unit #2 Unit #3 Unit #4
1
2
4
3
MAXIMUM OF 15 UNITS PER TRANSFORMER.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3
Important: Disconnect the first unit’s Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 3).
For subsequent Units, refer to instructions below...
C
1. Connect one end of the 10' EXTENSION (1) to the available terminal of the pervious unit’s Y-ADAPTER (2), and
the other end to the single terminal of the current unit’s Y-ADAPTER (3).
2. Connect SENSOR CABLE (4) to either of the two available terminals of Y-ADAPTER (3).
3. Repeat Steps above for each additional Unit, for a Max. of 15 Units on one AC POWER SUPPLY.