Installation Guide
7
M965985 Rev. 1.2 (3/21)
F
HAND WASH SENSOR OPERATION;
Fig. 7
REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN
INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately starts
to ow. Water ow will stop 1.5 seconds after user is out of
sensor range. This Comfort delay allows the user to
comfortably move their hands without the water turning off.
As a precaution, a Safety Timer will turn off the water after the
sensor has been blocked for 59 seconds. The water will stay off
until the blockage is removed from the detection zone.
The Comfort and Safety time settings can be adjusted using
the Optional Remote Control (605XRCT).
MAINTENANCE
A
REPLACE BATTERY; Fig. 8, 9
1. Remove 3 COVER SCREWS (1) and lift COVER (15) off.
2. Disconnect SENSOR CABLES (6) and (7) from the
BATTERY and SOLENOID VALVE. (Fig. 9)
3. Push BATTERY (17) forward and Pull it out. (Fig. 8)
4. Replace the new battery with the same placement.
(Insert terminal side rst)
B
CHANGE SENSOR RANGE; Fig. 8, 9
1. Remove 3 COVER SCREWS (1).
2. Remove the COVER (15).
3. Disconnect the BLACK POWER SUPPLY CONNECTOR (7)
and reconnect. Fig. 9.
4. While the SENSOR CONTROL LED (9) is blinking slowly,
place your hand 1 - 2 in. (25.4-50.8mm) in front of the sensor.
5. When the LED stops blinking and stays “ON”, move your hand
to the desired position and hold in place until the LED begins
to blink again.
6. Once the SENSOR CONTROL LED (9) begins to blink again,
remove your hand from the detection zone. When the ashing
stops, the detection distance is set.
7. Reassemble the COVER (15) and secure it with COVER
SCREWS (1).
C
ADJUST HOT LIMIT STOP; Fig. 5, 6
To reduce the amount of hot water that can mix with cold, the
installer can adjust hot limit stop (Four different settings).
1. Rotate LEVER HANDLE (5) counter-clockwise to its stop
position (100% cold).
2. Remove SET SCREW (3) and pull off the LEVER
HANDLE (5).
3. Pull out LIMIT STOP (1) from the SHAFT EXTENSION (8).
4. Rotate LIMIT STOP (1) between the shaded area and insert
back onto SHAFT EXTENSION (8).
5. Each notch on the LIMIT STOP (1) will reduce the amount of
hot water by approximately 3%. For example, the 2nd notch
will have 97% of maximum temp, the 3rd notch will have 94%
and the fourth will be 91%.
6. Replace LEVER HANDLE (5), SET SCREW (3) and tighten.
15
16
2
1
4
9
14
7
Fig. 8
Fig. 9
6
12
17
Fig. 4
DETECTION
ZONE
PROTECTIVE FILM
IMPORTANT: Do not
use sealent on threads
1
2
3
COLD
HOT
(3) INLINE
FILTER
Fig. 6
5
4
Fig. 5
1
9
8
7
5
3
1
Fig. 7