Technical Specifications
6/18
TOP OF
FIXTURE
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Roughing-in Dimensions
Right or Left Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" min. (152 mm) above fixture.
Consult Codes for details.
406 mm
(16")
152 mm
(6") MIN.
292 mm
(11-1/2")
-C-L-
-C-L-
114 mm
(4-1/2")
86mm
(3-3/8)
72 mm
(2-7/8")
DETECTION ZONE
400 -800 mm
(15-3/4 TO 31-1/2)
SUPPLY
DN 20 mm
(3/4"" I.P.S.)
15˚
FINISHED WALL
51 mm (2") HOLE
FOR CONDUIT
115 -134 mm
(4-1/2" TO 5-1/4")
FOR 3/4" TOP
SPUD FIXTURES
MANUAL
OVERRIDE
BUTTON
*CRITICAL
LEVEL
45
˚
180
˚
305 mm
(12") MAX.
160 mm
(6-1/4")
160 mm
(6-1/4")
57 mm (2-1/4") -
76 mm (3")
2-GANG ELECTRICAL
BOX BY OTHERS
OPTIONAL COVER PLATE
SELECTRONIC
®
SENSOR OPERATED
URINAL FLUSH VALVE
HARD-WIRED AC POWER, BASE MODEL
© 2018 AS America Inc.
Meets the American Disabilities Act Guidelines
and ANSI A117.1 Requirements for accessible
and usable building facilities - check local codes