Installation Guide
6
M965644 EN REV. 1.5 (9/15)
SUPPLY
(1" NPT)
Fig.9 (TOP SPUD FIXTURE ILLUSTRATED)
1
86mm
(3-3/8")
385mm
(15-1/8")
(51mm) 2" DIA.
HOLE FOR
CONDUIT
SMALL END
2
2
Hubbel-RACO 779
OR EQUAL
(BY CONTRACTOR).
Hubbel-RACO #256 OR EQUAL
(BY CONTRACTOR).
305mm
(12" MAX.)
1-1/2" TOP SPUD
(1" NPT)
BLACK & WHITE
POWER
CONNECTIONS
3
4
1
Fig.10
1
CONNECTOR NOT USED
IN THIS INSTALLATION
2
8
INSTALL POWER SUPPLY AND
MAKE ELECTRICAL CONNECTIONS;
Fig. 10, 10a
1. Mount POWER SUPPLY (1) into ELECTRICAL BOX (2).
Connect White and Black power connections to
POWER SUPPLY (1). Fig. 10.
2. Connect AC TRANSFORMER (1) to the single terminal
of the Y-ADAPTER (4). Fig. 10.
3. Connect the 27" EXTENSION CABLE (3) from the ush
valve cover to one of the two available terminals of
Y-ADAPTER (4). Fig. 10. If ELECTRICAL BOX (2) is
installed remotely, then connect the 10' EXTENSION
CABLE (sold seperately) to the 27" EXTENSION
CABLE (3) from the ush valve cover and secure this
connection by installing into CONNECTOR HOUSING
(5) as shown in Fig. 11.
8a
COVER PLATE FRAME AND
COVER PLATE INSTALLATION
(front installation only)
1. After POWER SUPPLY (1) is installed and wire
connections are completed, install the COVER PLATE
FRAME (5) onto the ELECTRICAL BOX (2). Fig. 10a.
2. Install the two tabs on the back side of the COVER
PLATE (6) into the two Slots located on the top edge of
the COVER PLATE FRAME (5). Push on bottom until it
snaps into place. Fig. 10a.
CAUTION: Use only American Standard supplied transformers
and cable sets. Using non-AS supplied cables, or cutting,
splicing or modifying any components will void the warranty.
ELECTRICAL INSTALLATION
CAUTION
Ensure that the line power to bathroom
is OFF prior to making connections.
REMOTE INSTALLATION OF ELECTRICAL BOX
(without cover plate)
Mount a 4" x 4" x 3-1/2" (102 x 102 x 89 mm),
ELECTRICAL BOX (1) (not supplied) within 10'
from the installed ush valve. See Fig. 11.
7
INSTALL ELECTRICAL BOX (NOT
SUPPLIED); Fig. 9
Fig.10a
TABS
S LOT
S LOT
5
6
2
FOR FRONT INSTALLATION (with cover plate)
Note: The ELECTRICAL BOX (1) can be installed in
any location along the marked arc.
Cut a 105 x 105 mm (4-1/8" x 4-1/8") opening in
nished wall for ELECTRICAL BOX (1) (not supplied)
and follow installation template provided in box.