Installation Guide

8
M965651 Rev. 1.5 (10/16)
TO ENSURE A LAMINAR WATER FLOW, the air must be
slowlypurgedfromthespout.Todoso,covertheSENSOR (1)
while slowly opening the water supply valves. When the water
owsasasolid,smooth,steadystream,uncoverthe
SENSOR (1) and fully open the water supply valve. Fig. 1.
A
HAND WASH SENSOR OPERATION; Fig. 1
When the Sensor detects a user, the water immediately starts
toow.Waterowwillstop2secondsafteruserisoutof
sensor range. The off delay allows the user to comfortably
movehishandswithouttheowcyclingonandoff.Asa
precaution, a safety timer will turn off the water after the
sensorhasbeenblockedfor59seconds.Thewaterwillstay
offuntiltheblockageisremovedfromthedetectionzone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
B
CHANGE SENSOR RANGE;
(Factory set at 6") Fig. 2, 2a
1. RemoveCONTROLBOXCOVER.DisconnectPowerSupply
(1), then reconnect. Fig. 2.
2.WhiletheSENSORCONTROLLED (2)isblinkingslowly,
placeyourhand1-2in.(30-50mm)infrontofthesensor.
Fig. 2a.
3.WhentheLEDstopsblinkingandstays“ON”,moveyour
handtothedesiredpositionandholdinplaceuntiltheLED
beginstoblinkagain.Fig. 2a.
4.OncetheSENSORCONTROLLED (2)beginstoblink
again,removeyourhandfromthedetectionzone.Whenthe
ashingstops,thedetectiondistanceisset.
5. Reinstall CONTROLBOXCOVERS(2). Tighten cover
screws rmly.
C
CLEAN FILTER ASSEMBLY; Fig. 3
1. Remove CONTROLBOXCOVER.
2.CloseSUPPLYSTOP(13)with4mmHexwrench.
Note: Activate sensor to keep water owing out of
faucet while shutting off.
3.UnthreadFILTERASSEMBLY (6)usinga7/16"socket.
4.PullouttheFILTERASSEMBLY(6), remove and clean
white debris cup and lter screen.
5.InstalltheFILTERASSEMBLY(6)backinitsplaceand
tightenwitha7/16"socket.
Caution: Do not over tighten.
6.OpenSUPPLYSTOP (13) with4mmHexwrench.
7. Reinstall CONTROLBOXCOVER.Tightencover
screws rmly.
Fig. 1
DETECTION
ZONE
1
Fig. 2
BLINKING LED
UP TO 10" (250mm)
1
2
BLINKING
LED
2
1" - 2" (30mm - 50mm
Fig. 2a
6
WHITE
DEBRIS
CUP
FILTER
SCREEN
Fig. 3
7/16" SOCKET
4mm HEX WRENCH
13
CAUTION
Before opening CONTROL BOX
disconnect AC power supply.
TEST INSTALLED FAUCET
MAINTENANCE