Installation Guide
8
M965651 Rev. 1.5 (10/16)
TO ENSURE A LAMINAR WATER FLOW, the air must be
slowlypurgedfromthespout.Todoso,covertheSENSOR (1)
while slowly opening the water supply valves. When the water
owsasasolid,smooth,steadystream,uncoverthe
SENSOR (1) and fully open the water supply valve. Fig. 1.
A
HAND WASH SENSOR OPERATION; Fig. 1
When the Sensor detects a user, the water immediately starts
toow.Waterowwillstop2secondsafteruserisoutof
sensor range. The off delay allows the user to comfortably
movehishandswithouttheowcyclingonandoff.Asa
precaution, a safety timer will turn off the water after the
sensorhasbeenblockedfor59seconds.Thewaterwillstay
offuntiltheblockageisremovedfromthedetectionzone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
B
CHANGE SENSOR RANGE;
(Factory set at 6") Fig. 2, 2a
1. RemoveCONTROLBOXCOVER.DisconnectPowerSupply
(1), then reconnect. Fig. 2.
2.WhiletheSENSORCONTROLLED (2)isblinkingslowly,
placeyourhand1-2in.(30-50mm)infrontofthesensor.
Fig. 2a.
3.WhentheLEDstopsblinkingandstays“ON”,moveyour
handtothedesiredpositionandholdinplaceuntiltheLED
beginstoblinkagain.Fig. 2a.
4.OncetheSENSORCONTROLLED (2)beginstoblink
again,removeyourhandfromthedetectionzone.Whenthe
ashingstops,thedetectiondistanceisset.
5. Reinstall CONTROLBOXCOVERS(2). Tighten cover
screws rmly.
C
CLEAN FILTER ASSEMBLY; Fig. 3
1. Remove CONTROLBOXCOVER.
2.CloseSUPPLYSTOP(13)with4mmHexwrench.
Note: Activate sensor to keep water owing out of
faucet while shutting off.
3.UnthreadFILTERASSEMBLY (6)usinga7/16"socket.
4.PullouttheFILTERASSEMBLY(6), remove and clean
white debris cup and lter screen.
5.InstalltheFILTERASSEMBLY(6)backinitsplaceand
tightenwitha7/16"socket.
Caution: Do not over tighten.
6.OpenSUPPLYSTOP (13) with4mmHexwrench.
7. Reinstall CONTROLBOXCOVER.Tightencover
screws rmly.
Fig. 1
DETECTION
ZONE
1
Fig. 2
BLINKING LED
UP TO 10" (250mm)
1
2
BLINKING
LED
2
1" - 2" (30mm - 50mm
Fig. 2a
6
WHITE
DEBRIS
CUP
FILTER
SCREEN
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Fig. 3
7/16" SOCKET
4mm HEX WRENCH
13
CAUTION
Before opening CONTROL BOX
disconnect AC power supply.
TEST INSTALLED FAUCET