Installation Guide

7
M965651 Rev. 1.5 (10/16)
Unit #2 Unit #3
Fig. 3
10 ft.
EXTENSION
CABLE
AC POWER
SUPPLY
AC HARDWIRE
POWER SUPPLY
*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
OR
Unit #1
Already installed
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All control box covers must be removed before beginning to make daisy-chain connections.
Disconnect the rst units Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 6).
For subsequent Units, refer to instructions below...
1. RemoveCOVERSfromallCONTROLBOXES (3).
2.Removesolidblackpluggrommetfromleftsideofall
CONTROLBOXES(3),andreplacewithGRAY
GROMMET (5b). (Supplied with each Faucet).
3. Insert pervious unit’s 10'EXTENSION (11a) through
grayGROMMET(5b) and connect to single terminal
ofY-ADAPTER(11).
4.Feed27"EXTENSIONCABLES (2) through the top of
CONTROLBOX (3).Connectone27"EXTENSION
CABLE(2)totheSOLENOIDCABLE (7), and the other
to either of the two available terminals of the
Y-ADAPTER(11). Connect the current unit’s 10'
EXTENSION (10a) to available terminal of the
Y-ADAPTER(11).
5.Feedtheotherendofthe10ft.EXTENSION(10b)
throughthetwoGRAYGROMMETS(6a and 6b) and
connect to the single terminal of the next unit’s
Y-ADAPTER (11).PlaceY-ADAPTER(11) into
CONTROLBOX (3).
6. Repeat Steps above for each additional Unit, for a
Max.of15UnitsononeACPOWERSUPPLY.
7. Reinstall CONTROLBOXCOVERS.Tightencover
screws rmly.
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or
cutting, splicing or modifying any components will void the warranty.
Unit #2 Detail
Fig. 3a
5
5b
10b
6a
6b
10a
7
2
2
11
11a
3