Installation Guide

6
M965651 Rev. 1.5 (10/16)
Fig. 2
10a
11
7
2
2
Fig. 2b
2
3
1
6
9
FROM ELECTRICAL BOX
WITH POWER SUPPLY
Fig. 2c
BLACK & WHITE
POWER
CONNECTIONS
15
13
CONNECTOR NOT
USED IN THIS
INSTALLATION
10b
14
4" ELECTRICAL BOX
OR EQUIVALENT BY
OTHERS
12
Fig. 2a
16
6
9
810
2
PLUG INTO
WALL OUTLET
7
B
AC VERSION; Fig. 2
PLUG-IN
HARDWARE
Note: For AC installation, make power supply connection
before mounting CONTROL BOX (3) to wall.
1. RemoveCONTROLBOXCOVER(1). Feed the
EXTENSIONCABLES(2) from the Faucet through
thetopofCONTROLBOX(3).InstallCONNECTOR
LOCKINGDEVICE(16). Fig. 2.
FOR AC PLUG-IN ONLY
2a.InsertPOWERCORD (8) throughPOWERSUPPLY
GROMMET (9). Connect it to the SINGLEACADAPTER
(10). Fig. 2a.
3a.InsertPOWERCORD(8)throughsideGROMMET (6)
as shown. Fig. 2a.
4a. Connect27"EXTENSIONCABLES (2)toSOLENOID
CABLE (7) andPOWERCORD(8). Fig. 2a.
5a. Mount CONTROLBOX to wall. Reinstall CONTROLBOX
COVER(1). Tighten cover screws rmly.
6a.PlugACPOWERSUPPLYintowalloutlet.
FOR AC HARDWIRE ONLY
2b. Insert one end of the 10'EXTENSION(10a) through
POWERSUPPLYGROMMET(9). Fig. 2b.
3b. Insert 10'EXTENSION (10a) through side
GROMMET (6) as shown. Fig. 2b.
4b.Connect10’EXTENSION(10a) to single terminal of
SINGLEACADAPTER (11). Fig. 2b.
5b.Connect27"EXTENSIONCABLES(2) toSOLENOID
CABLE (7) and to the available terminal of the
SINGLEACADAPTER(11).
6b. Mount CONTROLBOX (3) to wall. Reinstall CONTROL
BOXCOVER (1). Tighten cover screws rmly.
Contractor to supply ELECTRICAL BOX (12) and power
to POWER SUPPLY (13).
7b.MountPOWERSUPPLY (13) intoELECTRICAL
BOX (12).ConnectWhiteandBlackconnectionsto
POWERSUPPLYCONNECTIONS(14). Fig. 2c.
8b. Connect the10'EXTENSION(10b)tothePOWER
SUPPLYCABLE (15). Fig. 2c.
CAUTION
Disconnect AC power supply
before opening CONTOL BOX.
CAUTION: Use only American Standard supplied cable sets.
Using non-AS supplied cables, or cutting, splicing or modifying
any components will void the warranty.