Installation Guide
6
M965651 Rev. 1.5 (10/16)
Fig. 2
10a
11
7
2
2
Fig. 2b
2
3
1
6
9
FROM ELECTRICAL BOX
WITH POWER SUPPLY
Fig. 2c
BLACK & WHITE
POWER
CONNECTIONS
15
13
CONNECTOR NOT
USED IN THIS
INSTALLATION
10b
14
4" ELECTRICAL BOX
OR EQUIVALENT BY
OTHERS
12
Fig. 2a
16
6
9
810
2
PLUG INTO
WALL OUTLET
7
B
AC VERSION; Fig. 2
• PLUG-IN
• HARDWARE
Note: For AC installation, make power supply connection
before mounting CONTROL BOX (3) to wall.
1. RemoveCONTROLBOXCOVER(1). Feed the
EXTENSIONCABLES(2) from the Faucet through
thetopofCONTROLBOX(3).InstallCONNECTOR
LOCKINGDEVICE(16). Fig. 2.
FOR AC PLUG-IN ONLY
2a.InsertPOWERCORD (8) throughPOWERSUPPLY
GROMMET (9). Connect it to the SINGLEACADAPTER
(10). Fig. 2a.
3a.InsertPOWERCORD(8)throughsideGROMMET (6)
as shown. Fig. 2a.
4a. Connect27"EXTENSIONCABLES (2)toSOLENOID
CABLE (7) andPOWERCORD(8). Fig. 2a.
5a. Mount CONTROLBOX to wall. Reinstall CONTROLBOX
COVER(1). Tighten cover screws rmly.
6a.PlugACPOWERSUPPLYintowalloutlet.
FOR AC HARDWIRE ONLY
2b. Insert one end of the 10'EXTENSION(10a) through
POWERSUPPLYGROMMET(9). Fig. 2b.
3b. Insert 10'EXTENSION (10a) through side
GROMMET (6) as shown. Fig. 2b.
4b.Connect10’EXTENSION(10a) to single terminal of
SINGLEACADAPTER (11). Fig. 2b.
5b.Connect27"EXTENSIONCABLES(2) toSOLENOID
CABLE (7) and to the available terminal of the
SINGLEACADAPTER(11).
6b. Mount CONTROLBOX (3) to wall. Reinstall CONTROL
BOXCOVER (1). Tighten cover screws rmly.
Contractor to supply ELECTRICAL BOX (12) and power
to POWER SUPPLY (13).
7b.MountPOWERSUPPLY (13) intoELECTRICAL
BOX (12).ConnectWhiteandBlackconnectionsto
POWERSUPPLYCONNECTIONS(14). Fig. 2c.
8b. Connect the10'EXTENSION(10b)tothePOWER
SUPPLYCABLE (15). Fig. 2c.
CAUTION
Disconnect AC power supply
before opening CONTOL BOX.
CAUTION: Use only American Standard supplied cable sets.
Using non-AS supplied cables, or cutting, splicing or modifying
any components will void the warranty.