Installation Guide
4
M965651 Rev. 1.5 (10/16)
2
MOUNT CONTROL BOX; Fig. 2
NOTE: The illustration shows the Infection Control faucet
mounted on the American Standard Infection
Control Sink. Faucet can be installed on any sink or
countertop. For futher instructions regarding faucet
installation on the American Standard Infection
Control Sink, see instruction sheet No. 7301793-100
(Infection Control Sink System) supplied with Sink.
1. ForinstallationonInfectionControlSink,mount
CONTROLBOX(1)onMOUNTINGBRACKET(2) with
theSCREWS(3) provided.
2. Forallothersinksorcountertops,determinelocationof
CONTROLBOX(1).Itmustbelocatedwith-inthe14"
(356mm)by21"(533mm)shadedareashowninFigure 2 in
order for electrical connections from the spout assembly to
be made properly.
NOTE: CONTROL BOX SUPPLY HOSE is 20". Distance
between wall supply and CONTROL BOX (1) must
be taken into consideration.
3. RemovetapefromCONTROLBOXCOVER (6) and pull off
COVER(6).HoldtheCONTROLBOX (1) in desired location
andmarkthefourmountingholelocationsasshown.
NOTE: Find plastic bag containing 4 M5X16 screws to be
used for securing the CONTROL BOX (1) when
installation is complete.
NOTE: For AC installation, make power supply connection
before mounting CONTROL BOX (1) to wall.
4. It is recommended that the CONTROLBOX (1) be secured
to a wall stud or cross brace within the wall using the
SCREWS (3)supplied.IftheCONTROLBOX(1) is to be
installedontileorplasterwalls,theANCHORS (5) and
SCREWS(4) should be used.
3
CONNECT SPOUT HOSE TO CONTROL BOX;
Fig. 3
1. ConnectSUPPLYNUT(1) from spout hose to nipple on top
ofCONTROLBOX (2). Tighten with adjustable wrench to
makeawatertightconnection.Fig. 3.
4
CONNECT WATER SUPPLY TO CONTROL
BOX AND WALL SUPPLY; Fig. 4, 4a
NOTE: If using the optional Mixing Valve, see sheet
#M968808 for installation instructions.
1. InsertFIBERWASHER (4) intoSUPPLYNUT (1) on
CONTROLBOX (2).
2. ConnectFLEXIBLESUPPLYHOSE (3)toSUPPLYNUT (1)
onCONTROLBOX (2).Tightentomakeawatertight
connection. Use two wrenches to tighten if necessary. Fig. 4.
3. ConnectFLEXIBLESUPPLYHOSE (3) directly to wall
supply.ConnectiononFLEXIBLESUPPLYHOSE (3)is3/8"
compression. Use adjustable wrench to tighten connection.
Donotovertighten.Fig. 4a.
Note:FLEXIBLESUPPLYHOSE(3) measures 20" from
thebottomoftheCONTROLBOX (2) base. If additional
supply length is required, installer must purchase parts
separately.
Impor tant:IfFLEXIBLESUPPLYHOSE (3) is too long, loop to
avoidkinking.
Fig. 2
3-3/4"
(96mm)
2-3/4"
(71mm)
3"
(76mm)
6
4
5
2
2
3
1
1
MOUNTING
BRACKET
SUPPLIES
WASTE
ENCLOSURE
MOUNTING
HOLES
1524mm
(60)
20"
(500mm)
MOUNTING
BRACKET
14"
(356mm)
21"
(533mm)
Fig. 3
1
2
1
3
3
Fig. 4
2
COLD WATER OR
TEMPERED
WALL SUPPLY
OTHER SINK
INSTALLATION
Fig. 4a
4