1. Remove ENCLOSURE COVER (1). Fig. 2.
2. Feed the WIRE CONNECTORS (2) through the top
of ENCLOSURE (5). Fig. 2a.
3. Remove GROMMET (4) from ENCLOSUR (5). Fig. 2.
4. Feed the gray SENSOR WIRE (7) through
GROMMET (4), 4" from CONNECTOR. Fig. 2b. Insert
gray SENSOR WIRE (7) into SPLIT PLUG (9). Push
SPLIT PLUG (9) into GROMMET (4) to seal. Fig. 2e.
5. Insert GROMMET (4) back into ENCLOSURE (5).
Fig. 2d.
6. Remove SPLIT PLUG (11) from POWER SUPPLY
GROMMET (12). Insert POWER CORD CONNECTOR
(13) through POWER SUPPLY GROMMET (12). Insert
POWER CORD (14) into SPLIT PLUG (11). Push
SPLIT PLUG (11) into POWER SUPPLY GROMMET
(12) to seal. Fig. 2g.
7. Insert POWER SUPPLY CONNECTOR (13) into
RECEPTOR (15) on the CIRCUIT BOARD (3). Fig. 2c.
8. Install CIRCUIT BOARD (3) into ENCLOSURE (5)
with SENSOR WIRE (7) under BOARD. Fig. 2d.
9. Insert SENSOR WIRE CONNECTOR (8) into
CIRCUIT BOARD RECEPTOR (10) slot. Fig. 2f.
10. Connect wires from SENSOR to SOLENOID
VALVE (6) (Red to +, Black to -). Fig. 2d.
11. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.
AC VERSION; Fig. 2
2
4
POWER
SUPPLY
CORD
8
RED
6
Fig. 2d
Fig. 2e
7
4
9
1
3
4
7
5
4
4"
Fig. 2f
Fig. 2c
3
8
10
CAUTION
Before opening ENCLOSURE
disconnect AC power supply.
11
14
12
13
13
Fig. 2g
15
BLACK
5
2
Fig. 2a
5
7
M968809 Rev.1.4