Specification Sheet
N14
© 2019 AS America Inc.
spec_6042.453 Decorum 0.125GPF HE Urinal Rev. 4/19
DECORUM
®
0.125 GPF
HIGH EFFICIENCY URINAL SYSTEM
MANUAL FLUSH VALVE
NOTES:
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
159mm
(6-1/4")
547mm
(21-1/2")
REF.
483mm
(19")
396mm
(15-9/16")
102mm
(4")
C/L OF
OUTLET
338mm
(13-5/16")
8mm x 25mm
(5/16" x 1")
SLOT
FINISHED FLOOR
2" N.P.T.
FEMALE OUTLET
CONNECTION
13mm
(1/2")
271mm
(10-11/16")
356mm
(14")
419mm
(16-1/2")
MAX
610mm
(24")
OPTIONAL
191mm
(7-1/2")
*Note: The Critical Line (-C-L-) on Vacuum Breaker must
typically be a minimum of 6" (152mm) above fixture.
Consult Codes for details.
VALVE LEFT or RIGHT HAND INSTA LLATION
K2 HANGERS
SUPPLY
DN 20mm
(3/4" I.P.S.)
108mm-133mm
(4-1/4" to 5-1/4")
ROUGH-IN
DIMENSION
295mm
(11-1/2")
-C-L-
343mm
(13-1/2")
57mm
(2-1/4")
-C-L-
*CRITICAL
LEVEL
FINISHED WALL
BARRIER FREE
Fixture Compliance Certications -
Meets or Exceeds the Following Specications:
• ASME A112.19.2-2008/CSA B45.1-08 for Vitreous
China Fixtures
Valve Listings:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so top of rim is 432mm (17") MAXIMUM from finished floor
.