CONNECT SPRAY HOSE & INSTALL WEIGHTS
• Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLY HOSES (1, 2) directly to wall
supplies. Connection on tting supplies are 3/8"
compression. Connect left supply hose (Red Stripe) to Hot
wall supply. Connect right supply hose (Blue Stripe) to Cold
wall supply. Use adjustable wrench to tighten connections.
Do not over tighten.
*
Faucet supplies are 21" long from faucet base.
Note: If additional supply length is required, installer
must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are too long,
loop as illustrated to avoid kinking.
MAKE WATER SUPPLY CONNECTIONS
Push the SPRAY HOSE END (2) into the HOSE
CONNECTOR (1) slide down LOCKING COLLAR (3)
until it snaps into place to secure connection.
With HAND SPRAY (4) seated in SPOUT (5), install
WEIGHT (7) onto HOSE (6) 21 inches from the underside
of the sink deck and secure with SCREW (8).
6
7
8
21"
(610 mm)
1
2
4
5
3
RED
STRIPE
BLUE
STRIPE
1
2
COLD
HOT
4
CHECK CONNECTIONS FOR LEAKS
Move HANDLE into “off” position.
Turn on water supplies and check connections for leaks.
Operate HANDLE (1) up and down, left and right to
ushwater lines thoroughly.
Operate HAND SPRAY and check connections for leaks.
CHECK CONNECTIONS