Specification

8
M965686 Rev. 1.2 (4/16)
1
REMOVE
2
3
Turn ON water at main supply.
With HANDLE (1) in “off” position, unthread SPRAY (3) from HOSE (2).
Operate handle back to front, in COLD and HOT positions, to ush water
lines thoroughly.
Replace SPRAY (3) onto HOSE (2).
Please make sure that there is no cross threading.
9
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE:
- 5 -
Battery needs replacement:
Sensor will start to blink continuously every second.
This is the indication that the batteries are low in power.
Replace batteries in battery holder with Qty (4) AA alkaline
type batteries.
Batteries last approximately one year.
Always change all 4 batteries. Failure to replacing all 4
batteries at the same time may cause faucet electronics
to not work properly.
Reduced or distorted flow:
Debris or dirt accumulating at inlet or AERATOR MAY
CAUSE REDUCED OR DISTORTED FLOW.
A) Clean lter screen at inlet hoses.
B) Turn hot and cold water supply off. Open valve in mixed
position for two seconds to relief pressure close valve.
C) Disconnect inlet hoses at stop valve and clean screen
lter. If necessary remove screen lter and rinse at another
water source.
Aerator Clean Out
AERATOR may accumulate dirt causing distored and
reduced water ow. Remove AERATOR by using the
AERATOR KEY (9) and rinse to clear any debris.
Clean out the SCREEN (10) by removing
SPRAY HEAD (11).
Power failure (manual bypass):
In the event of a power failure, turn the BYPASS KNOB (1)
on the SOLENOID ASSEMBLY (2) to the “ON” position.
The faucet will be in MANUAL MODE (see section 5) and
the HANDLE (2) can be used to turn on and off the water.
SERVICE
7
1
2
1
2
4
5
6
6a
3
7
9
10
11
TEST INSTALLED FAUCET
SCREEN FILTER