Installation Guide

- 3 -
6
SERVICE
5
M985013 (3/19)
• Move HANDLE into “off” position.
Turn on water supplies and check connections for leaks.
Operate HANDLE up and down, left and right to ush
water lines thoroughly.
• Operate HAND SPRAY and check connections for leaks.
CHECK CONNECTIONS FOR LEAKS
CHECK CONNECTIONS
FOR LEAKS
If Faucet Drips, Proceed As Follows:
• Turn VALVE to OFF position.
Operate HANDLE several times from OFF to ON position. Do not apply excessive force.
Reduced Flow:
• Clean out spray head screen.
Clean out cartridge.
Clogged CARTRIDGE outlets or inlets may
cause reduced flow.
To clean, rst turn off water supply then:
Loosen HANDLE SCREW (1) and remove
HANDLE (2).
Unthread ESCUTCHEON CAP (3),
SNAP RING (4).
Lift CARTRIDGE (5) off MANIFOLD (6) and
remove CARTRIDGE SEALS (7).
Clean MANIFOLD (6), CARTRIDGE (5)
ports and SEALS (7).
Place SEALS (7) into CARTRIDGE PORTS (5a).
Place CARTRIDGE (5) onto MANIFOLD (6).
Replace ESCUTCHEON CAP (3), SNAP RING (4),
HANDLE (2), tighten HANDLE SCREW (1).
3
5
5a
2
4
1
6
7
7
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS: