Specifications
N120
© 2014 AS America Inc.
11/14
AFWALL
®
MILLENIUM
™
FloWise
®
1.1 GPF FLUSHOMETER TOILET SYSTEM
MANUAL FLUSH VALVE
BARRIER FREE
VALVE LEFT or RIGHT HAND INSTALLAT ION
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be a minimum of 6" (152mm) above
fixture. Consult Codes for details.
2859.016
2859.128
2856.128
2856.016
2856.111
(4) Ø 22mm
(7/8") HOLES
191mm
(7-1/2")
133mm
(5-1/4")
229mm
(9")
FINISHED
FLOOR
333mm
(13-1/8")
381mm
(15")
41mm
(1-5/8")
356mm
(14")
*CRITICAL
LEVEL
SUPPLY
DN 25mm
(1" I.P.S.)
-C-L-
108 -133mm
(4-1/4" to 5-1/4")
293mm
(11-1/2")
ROUGH-IN
DIMENSION
FINISHED WALL
C/L OF SEAT POST
HOLES 140 mm
(5-1/2") CENTER
660mm
(26")
73mm
(2-7/8")
343mm
(13-1/2")
470mm
(18-1/2")
NOTES:
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING
NOT RECOMMENDED).
SUGGESTED2mm(1/16)CLEARANCEBETWEENFACEOFWALLANDBACKOFBOWL.
TOCOMPLYWITHAREACODEGOVERNINGTHEHEIGHTOFVACUUMBREAKERON
THEFLUSHOMETERVALVE,THEPLUMBERMUSTVERIFYDIMENSIONSSHOWNFOR
SUPPLYROUGHING.
CARRIERFITTINGASREQUIREDTOBEFURNISHEDBYOTHERS.
PROVIDESUITABLEREINFORCEMENTFORALLWALLSUPPORT.
IMPORTANT:Dimensionsofxturesarenominalandmayvarywithintherangeof
tolerancesestablishedbyANSIStandardA112.19.2.
Thesemeasurementsaresubjecttochangeorcancellation.Noresponsibilityisassumed
foruseofsupersededorvoidedpages
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so that top of seat is 432 to 483mm (17" to 19") from the finished floor.
Fixture Compliance Certifications -
Meets or Exceeds the Following
Specifications:
•ASMEA112.19.2-2008/CSAB45.1-08
forVitreousChinaFixtures
Valve Listings:
•ASSE1037
•ANSI/ASMEA112.19.2
•ADACompliant