Installation Guide
1
FRAMING INSTRUCTIONS
1a. Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square (Fig. 1). It is
strongly recommended that an additional opening be provided for access to the drain components.
NOTE: Maximum weight support of 300 lbs without mortar. Mortar is required during
installation for user weights exceeding 300 lbs.
1b. Install drain components to the bath following the manufacturer’s instructions. See the roughing-in
drawing for suggested opening size and location dimensions in specication page. NOTE: This tub
requires the 1554000.XXX American Standard Slotted Overow Drain. Please review drain
instructions, included in the tub box.
Fig. 1
Each alcove stud
must be plumb
and square.
30" (762 mm)
4" (102 mm)
8" (203 mm)
3-1/4" (83 mm)
8-3/8"
(213 mm)
2" (51 mm)
Drain
8-1/4"
(210 mm)
14-5/8"
(371 mm)
31-1/4"
(794 mm)
20-7/8"
(530 mm)
14"
(356 mm)
14"
(356 mm)
30" (762 mm)
Drain Cutout
16" (406 mm)
2" (51 mm)
Min Drain Clearance
6" (152 mm)
(Typical)
60-1/8" (1527 mm) Min
60-1/4" (1530 mm) Max
Support Clip
Locations (4 total)