Specifications
Page 40
Milan Supply Company/Milan Engineered Systems
Model Inlet Size (in) Outlet Size (in) Flow Range (gpm)
V4000 1.25 1.25 10-40
V6000 1.5 1.5 15-60
The 4000 RCW Indexing Valve
•ABS Polymer Construction-High strength, non corrosive body for long
product life.
•Operates at low 10 GPM at Pressures of 25-75 PSI-Reliably automates
multiple zoned residential and small commercial wastewater systems.
The 6000 RCW Indexing Valve
•Metal Die Cast Body-Durable, long lasting, and capable of high pres-
sure applications.
•Operates at 15 GPM at Pressures of 25-150 PSI-Ideal for onsite pump-
fed wastewater and ef uent water applications.
•Built-in Atmospheric Vacuum Breaker-Releases any vacuum created
between the pump and the valve on shut down.
4000
4000 Series
Pressure Loss - 4 Outlet Valve
Flow (GPM) 10 20 30 40
PSI Loss 2.0 3.0 4.5 6.4
•Pressure Loss - 6 Outlet Valve
Flow (GPM) 10 20 30
PSI Loss 2.0 4.5 7.5
•Pressure Rating: 25-75 PSI
•4 Outlet Models have interchangeable Cams for 2-4 Zone Operation. 4402-4404
•6 Outlet Models have interchangeable Cams for 2-6 Zone Operation. 4602-4606
6000 Series
Pressure Loss - 4 Outlet Valve
Flow (GPM) 20 40 60 80 100
PSI Loss 2.5 3.5 5.0 7.5 10.0
Pressure Loss - 6 Outlet Valve
Flow (GPM) 20 40 60 80 100
PSI Loss 3.0 4.0 6.0 9.0 11.0
•Pressure Rating: 25-75 PSI
•4 Outlet Models have interchangeable Cams for 2-4 Zone Operation. 6402-6404
•6 Outlet Models have interchangeable Cams for 5-6 Zone Operation. 6605-6606
K-Rain Hydrotek Distributing Valve
Pressure Indexing Zone Valve
(Bare Valve Values)
OSI Valve Assembly
Chart
6000
(Bare Valve Values)
INSTALLATION DIAGRAM