Installation Guide
7301878-100 Rev. A
- 2 -
BACK-TO-BACK INSTALLATION
Recommended fitting type for
back-to-back installations.
Depending upon your plumbing and venting conditions, the flow from the Cadet
®
PRO in a
back-to-back installation may create a vacuum on the system and draw water from the opposing
bowl. The National Standards Plumbing Code prohibits the use of a cross fitting for drainage as
throw over is possible. The code does approve a directional "Y" style fitting with proper venting to
direct the water downward and away from the other toilet.
Press firmly.
Wax Ring
(sold separately)
1 2
Turn Off Water Supply
Flush to remove
water from tank;
sponge remaining
water from
bowl before
removing toilet.
Clean Flange
Before You Start:
If Removing An Existing Toilet
!
Caution: If leaving floor flange
open for more than 1-2 hours,
cover flange to prevent escaping
sewer gases.
ROUGHING-IN DIMENSIONS:
NOTE:
Distance from wall to closet flange centerline must be as listed on chart under ROUGH-IN DIMENSION “A”, the BOWL HEIGHT is listed as DIMENSION “B”.
FINISHED WALL
FINISHED
FLOOR
SUPPLY
AS
REQ'D.
A
BOWL SHAPE
RIGHT HEIGHT
®
12" (305mm) 16-1/2" (419mm) 215AA 3517A 4188A
ELONGATED 10" (254mm) 16-1/2" (419mm) 215AB 3517A 4188B
RIGHT HEIGHT
®
12" (305mm) 16-1/2" (419mm) 215BA 3517B 4188A
ROUND FRONT 10" (254mm) 16-1/2" (419mm) 215BB 3517B 4188B
COMPACT RIGHT 12" (305mm) 16-1/2" (419mm) 215FA 3517F 4188B
HEIGHT
®
ELONGATED 14" (356mm) 16-1/2" (419mm) 215FC 3517F 4188A
ELONGATED 12" (305mm) 15" (381mm) 215CA 3517C 4188A
10" (254mm) 15" (381mm) 215CB 3517C 4188B
ROUND FRONT 12" (305mm) 15" (381mm) 215DA 3517D 4188A
10" (254mm) 15" (381mm) 215DB 3517D 4188B
ROUGH-IN
DIM. “A”
COMBO
MODEL
BOWL
MODEL
TANK
MODEL
BOWL HEIGHT
DIM. “B”
B B