Installation Instructions
FILTER REPLACEMENT:
ActiFresh System
OPERATION AND MAINTENANCE
OPERATING INSTRUCTIONS:
CHARGING BATTERY:
Before operating, remove battery charger and battery pack from
packaging. Connect battery pack to battery charger using cable
included and connect to power supply.
When battery is fully charged, insert battery pack into battery holder.
Charge battery pack for 8 hours. While battery is charging RED
battery icon will illuminate. When battery is fully charged red
battery icon will turn off and WHITE power button will illuminate.
BATTERY PACK
INSERTION
INTO TANK
When battery needs re-charging, the
battery icon light will ash indicating
5% of battery life left.
Remove battery pack by depressing tab.
The springs will push the battery out
approximately 2 inches from the battery
holder. Pull out the battery pack by hand
until completely out of battery holder.
Connect to charger as described above.
Press tab on
battery holder
Odor coming from toilet
Fan is running after 5 minutes
Fan continues to run
a. ActiFresh system is not turned ON.
b. Battery Pack is not fully charged.
c. Battery Cable connection is not connected.
d. Carbon Filter needs replacement.
e. ActiFresh filter assembly is not correctly
attached to overflow tube.
f. Water Level in tank is incorrect.
a. Fan time out system not responding.
a. Power ON unit. (see ActiFresh System - Operating Instructions)
b. Charge Battery Pack. (see ActiFresh System - Operating Instructions)
c. Reconnect Battery Cable. (see step 8)
d. Replace filter. (see ActiFresh System - Operating Instructions)
e. Reattach filter assembly correctly. (see step 8)
f. Recheck water level in tank. (see step 8)
a. Press ON/OFF button on Battery Pack.
a. Remove battery pack and call Technical Support
Problem Possible Cause Corrective Action
ActiFresh System Troubleshooting
pg5
When lter needs changing the change lter logo will illuminate and ash.
Before proceeding to change lter ensure you have purchased a replacement
lter from americanstandard.com and search ActiFresh.
Remove tank lid.
Turn lter counter-clockwise (as indicated by arrow) to unscrew.
Discard used lter.
Install new lter by screwing clockwise until “stop” is
felt.
Replace tank lid.
Reset lter replacement light by pressing and holding down for
6 seconds.
FILTER
FILTER HOUSING
FILTER HOUSING WITH
FILTER INSTALLED
1
4
2
3
A
B
C
D
E
BATTERY ICON
LIGHT
BATTERY
PACK
BATTERY
CHARGER CABLE
POWER BUTTON
LIGHT
BATTERY LIGHT
POWER
BUTTON
FILTER
LOGO
Press power button to activate the ActiFresh
system BEFORE TOILET USE for optimal
effectiveness. The power button is located on
the right-hand side of the toilet tank. When
the system is powered on it will run for 4-1/2
minutes. After the 4-1/2 minute run time is
complete the system will automatically turn
off. Should more time be needed simply press
the power button again.