Specifications
AMERICAN RANGE
CORPORATION
MADE IN
USA
DESIGNED
a
BUILT
-16
WARNING
For optimal performance,
the
range should
be installed away from drafts that may be
caused
by doors, windows, and heating and
air conditioning outlets.
WARNING
The maximum depth of
the
overhead
cabinets
installed o
n either side of the
hood is
13 inches.
INSTALLATION
INSTRUCTIONS
The location selected for the range must meet the following criteria. If any of these criteria are not
met,
select another location.
Site Preparation
1. The range is a free standing
appliance.
If the range is
to be installed adjacent to cabinets, the clearances
shown below are
required.
2. This range may not be recessed into
the
cabinets.
The rear of the oven door
must
be beyond the edge
of the front face
of
the adjacent cabinet.
3. The gas and electrical supplies should be located
below the unit or in the adjacent right
cabinet.
4. Any openings in the wall behind the range and in the
floor under the range
must b
e sealed.
5. Always keep the appliance free and clear of
combustible materials, gasoline, or other flammable
vapors and
liquids.
6. Do not obstruct the flow of combustion exhaust and
ventilation air to the unit.
Electrical Service
All supply wiring and circuits must comply with National Electrical Codes and all Uniform Building
Codes
.
A 120 VAC,
60 Hz
separately grounded circuit that is protected by a 30A circuit breaker or time delay fuse
must be supplied to the appliance.
A 4-wire connection (not provided) is required to connect the appliance to
the
electrical supply
junction box, consult local building codes for the type and minimum wire gauge to
use.
The wiring to the appliance from the electrical supply junction box needs to
be
long enough to allow
the appliance to be pulled out from the wall for
service,
while remaining
connected.
Gas Supply
Be certain the appliance being installed is correct for the gas service
being
provided. Refer to the
appliance data plate for the gas supply requirements.
The minimum natural gas (NG) supply pressure required is 7 inches water column.
Minimum liquid propane (LP) gas supply pressure required is 11 inches water column
A manual gas shut-off valve must be remotely installed and easily accessible in the adjacent cabinet. The
regulator inlet is
for a
¾ inch
gas line. The appliance ships with a
½ inch
to
¾ inch
adapter connected to the
regulator.