Use and Care Manual
Section 3  Installation Instructions
3-3
Electrical Service
A 240VAC, 60Hz separately grounded circuit that is protected by a 30A circuit breaker or time 
delay fuse must be supplied to the appliance
A 4-wire connection (not provided) is required to connect the appliance to the electrical supply 
junction box. Consult local building codes for the type and minimum wire gauge to use.
The wiring to the appliance from the electrical supply junction box needs to be long enough to 
allow the appliance to be pulled out from the wall for service, while remaining connected.
Gas Supply
Be certain that the appliance being installed is correct for the gas service being provided. Refer 
to the appliance data plate for the gas supply requirements.
Minimum Natural Gas Supply Required – 6” water column
Minimum Liquid Propane (LP) Gas Supply Required – 11” water column
A manual gas shut-off valve must be remotely installed and easily accessible in the adjacent 
cabinet.
The regulator inlet is for a 3/4” gas line. The appliance ships with a 1/2” to 3/4” adapter 
connected to the regulator.
Preparing for Installation
Unpacking the Appliance
Unpack all parts boxes and verify that all of the required components have been provided. If any 
items are missing or damaged, please contact your dealer immediately. Do not install a damage 
or incomplete appliance.
♦  This Manual  ♦  4 Large and 2 Small Burner Assemblies
♦ Anti-Tip Kit
♦ 2 Racks
♦  3 Grates 
Removing the Oven Door
To make the appliance easier to move, remove the door to reduce weight. Open the door to its 
fully opened position.
Rotate the catch over the retaining arm on each hinge.
Lift the oven door to about a 15 degree angle from the vertical position.
Hold the door with both hands just below the handle and pull it away from the oven while 
continuing to lift.
Connecting the Electrical Service
Make sure that the conduit or appliance wire is long enough to allow the range to be pulled 
out for service without disconnecting it.
Connect the wires from the conduit or appliance wires to the wires on the appliance 
electrical panel.
Connecting the Gas Supply
Make sure the gas supply valve is in the off position.
Connect the gas line to the appliance.
Connect the gas line to the supply line.
Turn on the gas supply and check for leaks
Turn the gas supply off.
1.
2.
3.
1.
2.
1.
2.
3.
4.
5.
WARNING
It  is  the  owner’s  responsibility 
to  ensure  that  the  electrical 
connections  of  this  appliance  is 
performed by a qualified electrician. 
The  electrical  installation  must 
be  in  accordance  with the  latest 
version  of  the  National  Electrical 
code  ANSI/NFPA  70  and  local 
codes and ordinances.
WARNING
Check your local building codes for 
the  proper  method  of  installation. 
In  the  absence  of  local  codes, 
this  appliance  should  be installed 
in  accordance  with the  National 
Fuel  Gas  Code ANSI  Z223.1.  Be 
certain  that  the appliance  being 
installed  is  correct  for  the  gas 
service being provided.
IMPORTANT
Within  the  Commonwealth  of 
Massachusetts,  this  appliance 
must  be installed  by  a  licensed 
plumber or gas fitter.
WARNING
Do  not  attempt  to  disengage  the 
hinge catch with the door removed 
from  the  oven.  The  hinge  spring 
could  release  causing  personal 
injury.
Do  not  lift  or  carry the oven door 
by the door handle