AMERICAN RANGE CORPORATION INFORMATION FOR FUTURE USE: MODEL NUMBER: SERIAL NUMBER: PURCHASE DATE: INSTALLED BY: DATE: GAS TYPE: 0 ELECTRICAL INFORMATION: Toll Free 888.753.9898 www.americanrange.
AMERICAN RANGE CORPORATION TABLE OF CONTENTS WARNINGS & IMPORTANT SAFETY INSTRUCTIONS 7 PRODUCT DIMENSIONS 10 SPECIFICATIONS & ELECTRICAL REQUIREMENTS 1" CLEARANCE DIMENSIONS 15 GENERAL INSTRUCTIONS 13 INSTALLATION STEPS 17 PERFORMANCE CHECKLIST 25 FINAL PREPARATION 26 a .
AMERICAN RANGE CORPORATION IMPORTANT PLEASE READ AND FOLLOW! + BEFORE BEGINNING, PLEASE READ ALL INSTRUCTIONS CAREFULLY. + "DO NOT" REMOVE PERMANENTLY AFFIXED LABELS, WARNINGS, OR PLATES FROM PRODUCT. THIS MAY VOID THE WARRANTY. + ALL LOCAL AND NATIONAL CODES AND ORDINANCES MUST BE OBSERVED. INSTALLATION MUST CONFORM WITH LOCAL CODES. + THE INSTALLER MUST LEAVE THESE INSTRUCTIONS WITH THE CONSUMER WHO SHOULD RETAIN FOR LOCAL INSPECTOR'S USE AND FOR FUTURE REFERENCE.
AMERICAN RANGE CORPORATION IMPORTANT PLEASE READ AND FOLLOW! A GROUND FAULT INTERRUPTER (GF) SHALL BE USED AS REQUIRED BY PAN-70 (NATIONAL ELECTRIC CODE), FEDERAL/STATE/LOCAL LAWS, OR LOCAL ORDINANCES, « THE REQUIRED USE OF A GFI IS NORMALLY RELATED TO THE LOCATION OF A RECEPTACLE TO ANY SIGNIFICANT SOURCES OF WATER OR MOISTURE. « AMERICAN RANGE WILL NOT WARRANTY ANY PROBLEMS RESULTING FROM GFI OUTLETS WHICH ARE NOT INSTALLED PROPERLY OR DO NOT MEET THE REQUIREMENTS BELOW.
AMERICAN RANGE CORPORATION IMPORTANT PLEASE READ AND FOLLOW! ATTY NOT USE THE HANDLE OR OVEN DOOR TO LIFT THE OVEN. REMOVE PULL DOWN DOOR BEFORE INSTALLATION TO ENSURE THAT IT IS NOT USED TO LIFT THE UNIT. MAKE SURE PINS ARE INSERTED INTO HINGES BEFORE REMOVING DOOR TCG PREVENT INJURY TO HANDS AND/OR FINGERS. THE MISUSE OF THE OVEN DOOR(S) (E.G. STEPPING, SITTING, OR LEANING ON THEM) CAN RESULT IN HAZARDS OR INJURIES AND DAMAGE TO THE PRODUCT. A WARNING THIS APPLIANCE SHOULD NOT BE USED FOR SPACE HEATING.
AMERICAN RANGE CORPORATION SPECIFICATIONS & ELECTRICAL REQUIREMENTS DUAL FUEL 30" & 36" RANGES DESCRIPTION 30"W. MODELS 36" W. MODELS OVERALL WIDTH 35-718" TO TOP OF SIDE TRIM 36-114" OVERALL HEIGHT LEGS ADJUST OVERALL DEPTH 30-172" ADDITIONS TO BASE HEIGHT TO ISLAND TRIM GAS REQUIREMENTS NATURAL & 11" LP GAS MANIFOLD PRESSURE NATURAL & 10" LP ELECTRICAL REQUIREMENTS 240 VAG, 60Hz SINGLE PHASE MAX.
AMERICAN RANGE CORPORATION SPECIFICATIONS & ELECTRICAL REQUIREMENTS DUAL FUEL 48" & 60° RANGES DESCRIPTION 48" W. MODELS 60" W. MODELS OVERALL WIDTH 47-718" TO TOP OF SIDE TRIM 36-114" OVERALL HEIGHT LEGS ADJUST OVERALL DEPTH 30-172" ADDITIONS TO BASE HEIGHT TO ISLAND TRIM GAS REQUIREMENTS NATURAL & 11" LP GAS MANIFOLD PRESSURE NATURAL & 10" LP ELECTRICAL REQUIREMENTS 240 VAG, 60Hz SINGLE PHASE MAX.
AMERICAN RANGE CORPORATION GENERAL INSTRUCTIONS RANGE LOCATION: THE LOCATION SELECTED FOR THE RANGE MUST MEET THE FOLLOWING CRITERIA. IF ANY OF THESE CRITERIA ARE NOT MET, SELECT ANOTHER LOCATION. CABINET PREPARATION: 1. THE RANGE IS A FREE STANDING APPLIANCE. IF THE RANGE IS TO BE INSTALLED ADJACENT TO CABINETS, THE CLEARANCES SHOWN ON CLEARANCE DIMENSIONS PAGE ARE REQUIRED. . THIS RANGE MAY NOT BE RECESSED INTO THE CABINETS.
AMERICAN RANGE CORPORATION GENERAL INSTRUCTIONS » DO NOT REMOVE PROTECTIVE PACKAGING UNTIL YOU ARE READY TO PERFORM THE INSTALLATION. « DO NOT REMOVE THE PROTECTIVE WRAPPING FROM THE PRODUCT CONTROL PANEL UNTIL THE PRODUCT IS INSTALLED. * CAUTION THE APPLIANCE |S HEAVY. USE EXTREME CARE WHEN HANDLING! » USE PROPER EQUIPMENT TO MOVE PRODUCTS. USE OF A HYDRAULIC LIFT IS RECOMMENDED FOR THE INSTALLATION OF LARGER APPLIANCES. « ANY OPENINGS IN THE WALL AND IN THE FLOOR BEHIND CR UNDER THE OVEN MUST BE SEALED.
AMERICAN RANGE CORPORATION CLEARANCE DIMENSIONS Noy, Sor 3 “a RANGE A" WIDTH DIMENSION 20718" 30" 3578 36" arm 48 59.
AMERICAN RANGE CORPORATION INSTALLATION STEPS & OPEN DOOR COMPLETELY. PLACE PINS, SUPPLIED WITH UNIT IN PIN HOLE. FOR PERSONAL SAFETY, ONLY USE PINS SUPPLIED WITH THE UNIT. sie 2] REMOVE HINGE TRIM SCREWS, TAKE OFF HINGE TRIM, IDENTIFY RIGHT AND LEFT HINGE FOR FUTURE RE-INSTALLATION.
AMERICAN RANGE CORPORATION ses 3 CLOSE UNTIL PINS STOP DOOR. HOLD THE DOOR WITH BOTH HANDS JUST BELOW THE HANDLE AND PULL IT AWAY FROM THE OVEN WHILE CONTINUING TO LIFT.
AMERICAN RANGE CORPORATION sis 5 REMOVE RACKS. MEASURE THE FOUR CORNERS IN CUTOUT AREA TO VERIFY THAT FLOORING IS LEVEL.
AMERICAN RANGE CORPORATION owes 7 FOR UNEVEN OR SLOPED FLOORS, LEVEL UNIT WITH METAL SHIMS ONLY, AS THE ADJUSTMENT REQUIRED MAY EXCEED THE THREAD AVAILABLE IN THE LEG. MOVE UNIT INTO OPENING.
AMERICAN RANGE CORPORATION CHECK THAT UNIT IS LEVEL SIDE TO SIDE AND FRONT TO BACK. SIDE TRIM OF THE HIGH CORNER MUST BE 3/8" ABOVE COUNTER TOP. PULL OVEN STRAIGHT QUT. INSTALL ANTI-TIP DEVICE ACCORDING TO INSTALLATION INSTRUCTIONS FOUND INSIDE THE ANTI-TIP DEVICE KIT.
AMERICAN RANGE CORPORATION CONNECT GAS AND ELECTRICAL SUPPLIES BEFORE OPERATING APPLIANCE ALWAYS CHECK FOR GAS LEAKS. THIS MUST BE PERFORMED BY YOUR DEALER, A QUALIFIED LICENSED PLUMBER, OR GAS SERVICE COMPANY. A Gas pressure regulator B Adapter (must have 1/2" male pipe thread) C Flexible connector D Manual gas shutoff valve E 3/4" or supply F Use pipe-joint compound AVOID RISK OF PERSONAL INJURY OR DEATH; LEAK TESTING OF THE APPLIANCE MUST BE CONDUCTED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS.
AMERICAN RANGE CORPORATION sere 12 REPLACE DOOR. OPEN DOOR COMPLETELY. PUT HINGE TRIM PLATES BACK ON. SECURE WITH SCREW.
AMERICAN RANGE CORPORATION PERFORMANCE CHECKLIST BURNER CAPS ARE PACKED IN A SEPARATE BOX WITH THE GRATES. PLACE BURNER ON TOP OF RANGE.
AMERICAN RANGE CORPORATION PERFORMANCE CHECKLIST A QUALIFIED INSTALLER SHOULD CARRY OUT THE FOLLOWING CHECKS: REFER TC USER MANUAL TO PERFORM THE FOLLOWING CHECK POINTS. 1. CHECK OPERATION OF BAKE AT 350° CHECK OPERATION OF CONVECTION BAKE. CHECK OPERATION OF BROIL FUNCTION. CHECK OPERATION OF TOP BURNERS. CHECK OPERATION OF OVEN LIGHT. CHECK OPERATION OF ALL INDICATOR LIGHTS ON CONTROL PANEL. FINAL PREPARATION 1. SOME STAINLESS STEEL PARTS MAY HAVE A PLASTIC PROTECTIVE WRAP, WHICH MUST BE PEELED OFF.