User manual

75 PCE-5125 User Manual
Appendix A Programming the Watchdog Timer
Table A.1: Watchdog timer registers
Address of
register (2E)
Attribute
Read/Write
Value (2F)& description
87 (hex) -----
Write this address to I/O address port 2E (hex) twice to
unlock the W83627DHG-P
07 (hex) write Write 08 (hex) to select register of watchdog timer.
30 (hex) write
Write 01 (hex) to enable the function of the watchdog
timer. Disabled is set as default.
F5 (hex) write
Set seconds or minutes as units for the timer. Write 0 to
bit 3: set second as counting unit. [default]. Write 1 to bit
3: set minutes as counting unit
Unlock
Select register of
watchdog timer
Enable the function of
the watchdog timer
Use the function of
Lock
the watchdog timer
W83627DHG-P
W83627DHG-P