Owner`s manual

18
SPECIAL FEATURES
Use these features to change the following operations:
Efficiency mode
Maximum days between recharges
Auxiliary control (described on Page 19)
Chemical feed volume* (described on Page 19)
Chemical feed timer* (described on Page 19)
97% feature
Service reminder (described on Page 20)
To display one these screens:
1. From any of the rolling status screens, press the
SELECT () button to display the Main menu.
2. Press the DOWN () button to scroll through the
menu options until Advanced settings is highlighted
(See Figure 67).
FIG. 68
4. Press the DOWN () button to scroll through the
menu options until Special features is highlighted.
5. Press the SELECT () button to display the Special
features menu (See Figure 69).
FIG. 67
3. Press the SELECT () button to display the
Advanced settings menu (See Figure 68).
FIG. 69
6. Press the DOWN () button to scroll through the
menu options until the desired option is highlighted
(See list at the top of this column).
7. Press the SELECT () button to display the desired
information screen (See Figures 70-72).
8. See the right column on this page for specific
instructions on each cycle time screen.
9. Press the SELECT () button. The display will go
back to the Special features menu (Figure 69).
10. Press the LEFT () button three times to return to
the rolling status screens.
*
Only displayed if Auxiliary control is set to Chemical feed.
FIG. 70
FIG. 71
FIG. 72
8a. Efficiency mode: If the desired efficiency
mode already has a black dot next to it (See
Figure 70), go to Step 9. Otherwise, press the
DOWN () or UP () buttons to scroll to the
desired efficiency mode, then press SELECT
() to choose it.
Salt efficient limits available salt doses to
maintain 4000 grains/lb. of salt efficiency.
Units may recharge more frequently.
Auto adjusting is the default. It automati-
cally adjusts salt doses to target a 3-4 day
interval between recharges. Recommended.
High capacity is for applications where very
low “bleed” (less than 1.5 ppm) of hardness
can be tolerated. Such applications include
water for boilers. This setting will consume
higher quantities of salt.
8b. Maximum days between recharges: Press
the UP () or DOWN () buttons to change
the number of days (See Figure 71). The fea-
ture can be set from 1 to 15 days. Setting the
number of days below 1 turns the feature off
and defaults to automatic control of recharging.
8c. 97% feature: If the desired option already has
a black dot next to it (See Figure 72), go to
Step 9. Otherwise, press the DOWN () or
UP () buttons to scroll to the other option,
then press SELECT () to choose it. If this
feature is On, the softener will automatically
recharge when 97% of capacity is used, at any
time of day. Default is Off.
ECOWATER
SYSTEMS
Conditioner Operation