Specifications

10 INSTALLATION AND SERVICE GUIDE
SpeedDome Ultra III Camera Dom
e
8000-2573-01, REV.
B
CAUTIONS
If using an RS422 communication line, use
shielded cable and do not exceed 10 devices
per daisy chain.
If using a SensorNet communication line, use
unshielded cable and do not exceed 32 devices
per daisy chain.
The maximum length of power cable allowed
between the Class 2 LPS (low voltage) ac
source, such as a J-box, and the dome is
250m (820').
Do not run the composite cable, or camera
power cable (if used), adjacent to or in the
same conduit as line voltage mains power.
When wiring cables directly to the dome,
ALWAYS connect the video cable to the dome
before you connect the 9-pin cable (which
contains power). If you connect the 9-pin cable
first, you risk shorting delicate electronics near
the connector.
I/O PC board (when used).
If a cable clamp is on this board, remove it,
as it could damage cable connectors in the
housing during assembly.
Use a jeweler’s 2.5mm (0.1") slotted
screwdriver to tighten connector screws. Do
not overtighten these screws.
Use the dust cover when shipping the I/O
board back to the manufacturer. It will
protect the spring-finger connector.
When connecting the housing and eyeball
assembly to an outdoor housing:
Remove both slot covers to keep the
camera from overheating.
Keep the composite cable away from the
heater assembly.
Place tubing around the BNC connectors to
avoid shorting their metal surface to the
outdoor housing.
Check heater fans. Both fans must be on to
prevent overheating.
Note:
For further information, see installation
instructions shipped with the outdoor housing.
If disassembling the dome:
Dome contains electrostatic-sensitive
devices! Use a ground strap when handling
PC boards.
Once disassembled, parts of housing and
eyeball assembly are “extremely fragile” and
may break. Proceed using extreme care!