Specifications

SPEEDDOME ULTRA VI 8000-2830-03, REV. C
INSTALLATION AND SERVICE GUIDE 17 of 34
Figure 16. Test switch/LEDs on I/O board
Comm. LED
Power LED
RS422 Test
Pushbutton
10. Set dome address (Figure 17).
Recessed at top of housing and eyeball
assembly are three rotary address switches.
Address range is from 001 to 255, except for
Manchester, which is 01 to 64.
Set switches from most significant bit (MSB)
to least significant bit (LSB). For example:
For address 166, set SW3 to 1, SW2 to 6,
and SW1 to 6.
Figure 17. Setting address switches
090909
MSB
LSB
SW3
SW1SW2
11. Connect the housing and eyeball assembly to
the base (Figure 18) by aligning the Cap and
Base tabs and then turning clockwise until you
hear a click.
Figure 18. Connecting housing and eyeball
assembly to base(cables and lanyard
not shown)
12. Wait a few seconds for dome to begin its
homing routine. Homing routine indicates that
address was placed into dome memory and that
dome is ready for programming.
SW1
Align tabs on
Cap and Base.
Turn clockwise
to latch