Technical data
SPEEDDOME ULTRA  8 CONFIGURATION UTILITY  8200-0600-01, REV. C 
OPERATOR’S GUIDE
90 of 138 
dome is being initialized (Figure 82). After initialization is complete, the Dome 
Information screen is redisplayed. 
•  If you do not want to clear dome user-programmed data and set to factory defaults, select 
NO to cancel the initialization process and return to the Dome Information screen. 
Note: The Init Dome command erases all memory content from the IO board, 
including all presets and patterns that have been saved. Whenever you update 
the dome firmware, it is important to use the Init dome command after the 
upgrade has completed. 
Figure 82. Initializing dome screen 
Using the Calibration Screen 
(Indoor and outdoor domes) Calibration refers to using the configuration utility to define a 
zero reference point (or target) from which all other camera targets will be referenced when a 
dome is replaced on a base. 
Note: This procedure is only performed when an installed camera dome is 
replaced by another dome in an existing base. The new dome then can be 
calibrated to conform with the data already stored in the dome base. 
During calibration, the replacement camera is pointed at the desired target, which is the first 
object the dome being replaced was set to and whose position was initially recorded in the base 
memory. This object becomes the calibration reference point for the new dome camera. This 
should be a permanent object that will not or cannot be moved, such as a door, and its position 
should be written down for future reference. 
 Init Dome! 
 Initializing 