Technical data
SPEEDDOME ULTRA  8 CONFIGURATION UTILITY  8200-0600-01, REV. C 
OPERATOR’S GUIDE
40 of 138 
8.  When the Alarm/Areas/Home/PZ screen appears, select Exit. The Dome Configuration 
Menu appears. 
Configuring Normal Input States for Alarms 
IMPORTANT 
Some controllers allow the normal input states for domes to be specified at the 
controller. These controllers include VM96, AD matrices with AD2083-02A code 
units or AD168 matrix with the AD168CCM or AD2083-02A code unit. Do not use 
both the dome configuration utility and the controller to assign the normal input 
states. Use only the dome configuration utility or the controller to assign the 
normal input states. 
The normal input state for an alarm is the state that the device maintains when an alarm is not 
occurring. For example, you have a smoke detector connected to a dome input. Under normal 
circumstances, the smoke detector should not be detecting smoke. When smoke is detected, the 
alarm input changes states (from open to closed) and an alarm is issued. 
To configure the normal state for the alarm, select Set Alarm States from the 
Alarm/Areas/Home/Presets/PZ screen. The following screen appears: 
Figure 30. Set Alarm States screen 
Use this screen to assign open or closed as the normal state for the dome alarm inputs. When 
an input state changes from normal to abnormal and an internal alarm action is associated with 
the input, the alarm is triggered. The normal state is used by both internal alarms and controller 
defined alarms. 
 SET ALARM STATES
 INTERNAL ALARMS 
 INPUT  NORMAL STATE 
 1  OPEN 
 2  OPEN 
 3  OPEN 
 4  OPEN 
 EXIT 










