Technical data
SPEEDDOME ULTRA  8 CONFIGURATION UTILITY  8200-0600-01, REV. C 
OPERATOR’S GUIDE
38 of 138 
Configuring Alarm Actions 
IMPORTANT 
When operating on Manchester networks, the dome can be programmed to respond 
to any of the four available alarm inputs. However, the dome cannot transmit alarm 
input states to the host controller. If transmitting the alarm state to the host controller 
is required, the alarm device must be wired directly to the host controller. 
The dome provides four alarm inputs. By connecting alarm devices, such as smoke alarms, 
twilight sensors, or motion sensors, to these inputs, you can enhance the usability of your 
video surveillance system. You can further improve your video surveillance by assigning a 
dome action, such as a preset or pattern, to start whenever an alarm input changes from normal 
to abnormal. 
When Set Alarm Actions is selected from Alarms/Areas/Home/Presets/PZ screen, the 
following screen appears: 
Figure 29. Set Alarm Actions screen 
Use this screen to assign a preset or pattern to occur whenever the alarm's input state changes 
from normal to abnormal. You may also choose to have no action occur when the alarm's input 
state changes. 
Alarms can be processed internally by the dome, externally by the controller, or both. You 
may choose to send changes in the input state to the host controller. If the changes in input 
state are sent to the host controller, the host actions have higher priority than the associated 
dome actions. 
Note: An active internal alarm only resets when the input state changes to 
“normal.” A manual reset is not available. 
 SET ALARM ACTIONS
 INPUT ACTION 
 1 NO ACTION 
 2 NO ACTION 
 3 NO ACTION 
 4 NO ACTION 
 SEND INPUTS TO HOST? YES 
 EXIT 