Technical data
SPEEDDOME ULTRA  8 CONFIGURATION UTILITY  8200-0600-01, REV. C 
OPERATOR’S GUIDE
107 of 138 
Tested Pelco Equipment 
The following Pelco equipment has been tested with the SpeedDome Ultra 8 camera dome: 
•  Pelco 9760CTX 
•  Pelco MPT 9500 
Supported Pelco Features 
The SpeedDome Ultra 8 camera dome supports Left and Right Scan Limits, Auto Scan, 
Frame Scan and Random Scan when installed under the Pelco Coaxitron and “P” Protocol 
environment. The following commands are supported: 
If you want to...  Use... 
Program the Left Scan Limit 
Set Preset 92 
Program the Right Scan Limit 
Set Preset 93 
Activate Auto Scan 
Call Preset 99 
Activate Frame Scan 
Call Preset 98 
Activate Random Scan 
Call Preset 97 
Deactivate Auto, Frame or Random Scan 
Call Preset 96 
 Setting Left and Right Scan Limits 
Scan Limits allow you to set left and right boundaries for use with the Auto Scan, Frame Scan, 
and Random Scan functions. If the scan limits are not set, the dome pans continuously to the 
right when these functions are activated. 
IMPORTANT 
You must program the Left Scan Limit setting before programming the Right Scan 
Limit setting. This procedure erases any previously programmed Right Scan Limit 
setting. 
To program the Scan Limits: 
1.  Select the camera number assigned to the SpeedDome Ultra 8 camera dome. 
2.  Use the pan/tilt control to position the dome’s pointing direction to the Left Scan Limit. 
3. Enter Set Preset 92 to save the setting. 
4.  Position the dome’s pointing direction to Right Scan Limit. 
5. Enter Set Preset 93 to save the setting. 