Technical data

SPEEDDOME ULTRA 8 CONFIGURATION UTILITY 8200-0600-01, REV. C
OPERATOR’S GUIDE
107 of 138
Tested Pelco Equipment
The following Pelco equipment has been tested with the SpeedDome Ultra 8 camera dome:
Pelco 9760CTX
Pelco MPT 9500
Supported Pelco Features
The SpeedDome Ultra 8 camera dome supports Left and Right Scan Limits, Auto Scan,
Frame Scan and Random Scan when installed under the Pelco Coaxitron and “P” Protocol
environment. The following commands are supported:
If you want to... Use...
Program the Left Scan Limit
Set Preset 92
Program the Right Scan Limit
Set Preset 93
Activate Auto Scan
Call Preset 99
Activate Frame Scan
Call Preset 98
Activate Random Scan
Call Preset 97
Deactivate Auto, Frame or Random Scan
Call Preset 96
Setting Left and Right Scan Limits
Scan Limits allow you to set left and right boundaries for use with the Auto Scan, Frame Scan,
and Random Scan functions. If the scan limits are not set, the dome pans continuously to the
right when these functions are activated.
IMPORTANT
You must program the Left Scan Limit setting before programming the Right Scan
Limit setting. This procedure erases any previously programmed Right Scan Limit
setting.
To program the Scan Limits:
1. Select the camera number assigned to the SpeedDome Ultra 8 camera dome.
2. Use the pan/tilt control to position the dome’s pointing direction to the Left Scan Limit.
3. Enter Set Preset 92 to save the setting.
4. Position the dome’s pointing direction to Right Scan Limit.
5. Enter Set Preset 93 to save the setting.